;******************************************************************************* ;** ** ;** INTEL CONFIDENTIAL ** ;** ** ;** Copyright 2007-2014 Intel Corporation All Rights Reserved. ** ;** ** ;** The material contained or described herein and all documents related ** ;** to such material ("Material") are owned by Intel Corporation or its ** ;** suppliers or licensors. Title to the Material remains with Intel ** ;** Corporation or its suppliers and licensors. The Material contains trade ** ;** secrets and proprietary and confidential information of Intel or its ** ;** suppliers and licensors. The Material is protected by worldwide ** ;** copyright and trade secret laws and treaty provisions. No part of the ** ;** Material may be used, copied, reproduced, modified, published, ** ;** uploaded, posted, transmitted, distributed, or disclosed in any way ** ;** without Intel's prior express written permission. ** ;** ** ;** No license under any patent, copyright, trade secret or other ** ;** intellectual property right is granted to or conferred upon you by ** ;** disclosure or delivery of the Materials, either expressly, by ** ;** implication, inducement, estoppel or otherwise. Any license under such ** ;** intellectual property rights must be express and approved by Intel in ** ;** writing. ** ;** ** ;******************************************************************************* ; ;******************************************************************************* ; INF for Intel(R) 10 Gigabit PCIe Network Adapters ;******************************************************************************* ; [Version] Signature = "$Windows NT$" Class = Net ClassGUID = {4d36e972-e325-11ce-bfc1-08002be10318} Provider = %Intel% CatalogFile = ixn64x64.cat DriverVer = 03/06/2014,3.9.58.0 [Manufacturer] %Intel% = Intel, NTamd64.6.3 [Intel] [Intel.NTamd64.6.3] ; DisplayName Section DeviceID ; ----------- ------- -------- %O10A6.DeviceDesc% = NO_DRV, PCI\VEN_8086&DEV_10A6 %N10F7.KX4.Dual.Description% = N10F7, PCI\VEN_8086&DEV_10F7&SUBSYS_000D8086 %N10F7.KX4.FEM.Description% = N10FC, PCI\VEN_8086&DEV_10F7&SUBSYS_7B12108E %N10F7.Generic.Description% = N10FC, PCI\VEN_8086&DEV_10F7 %N1514.KX4.Dual.Description% = N1514, PCI\VEN_8086&DEV_1514&SUBSYS_000B8086 %N10F8.KX4.KR.Dual.Description% = N10F8_NoSec, PCI\VEN_8086&DEV_10F8&SUBSYS_000C8086 %N10F8.KR.NDC.Description% = N10F8_NDC, PCI\VEN_8086&DEV_10F8&SUBSYS_1F631028 %N10FB.SFI.Dual.Description% = N10FB, PCI\VEN_8086&DEV_10FB&SUBSYS_7B11108E %N1507.SFI.Dual.Description% = N10FB, PCI\VEN_8086&DEV_1507&SUBSYS_7B10108E %N1517.KR.Dual.Description% = N10FC, PCI\VEN_8086&DEV_1517&SUBSYS_006A1137 %HP10F8.KR.BLOM.Description% = HP10F8, PCI\VEN_8086&DEV_10F8&SUBSYS_18D0103C %HP10F8.KR.Dual.Description% = HP10F8, PCI\VEN_8086&DEV_10F8&SUBSYS_17D2103C %HP10FB.SFI.ALOM.Description% = HP10FB_ALOM, PCI\VEN_8086&DEV_10FB&SUBSYS_17D0103C %HP10FB.SFI.ALOM.SP.Description% = HP10FB_SP, PCI\VEN_8086&DEV_10FB&SUBSYS_211B103C %HP10FB.SFI.LOM.Description% = HP10FB_ALOM, PCI\VEN_8086&DEV_10FB&SUBSYS_2159103C %N10FB.OCP.DP.Generic.Description% = N10FB_OCP, PCI\VEN_8086&DEV_10FB&SUBSYS_00088086 %N1557.OCP.SP.Generic.Description% = N1557_OCP, PCI\VEN_8086&DEV_1557&SUBSYS_00018086 %N10FB.SFI.FLEXLOM.Description% = N10FB_PM, PCI\VEN_8086&DEV_10FB&SUBSYS_107117AA %HP10FB.SFI.Dual.Description% = HP10FB, PCI\VEN_8086&DEV_10FB&SUBSYS_17D3103C %N10F8.Generic.Description% = N10F8, PCI\VEN_8086&DEV_10F8 %N152A.Generic.Description% = N10F8, PCI\VEN_8086&DEV_152A %N10F9.Generic.Description% = N10FC, PCI\VEN_8086&DEV_10F9 %N10FB.Generic.Description% = N10FB_PM, PCI\VEN_8086&DEV_10FB&SUBSYS_11A91734 %N10FB.SFI.Dual.Description% = N10FB_NOSEC, PCI\VEN_8086&DEV_10FB&SUBSYS_7A118086 %N10FB.CopperDA.Dual.Description% = N10FC, PCI\VEN_8086&DEV_10FB&SUBSYS_00028086 %N10FB.SFI.Single.Description% = N10FB_SP, PCI\VEN_8086&DEV_10FB&SUBSYS_000A8086 %N10FB.SFI.Single.Description% = N10FB_SP, PCI\VEN_8086&DEV_10FB&SUBSYS_00068086 %N10FB.SFI.Dual.Description% = N10FB, PCI\VEN_8086&DEV_10FB&SUBSYS_00038086 %N10FB.SFI.Dual.Description% = N10FB, PCI\VEN_8086&DEV_10FB&SUBSYS_000C8086 %N10FB.SFI.Dual.Description% = N10FB, PCI\VEN_8086&DEV_10FB&SUBSYS_7A128086 %N10FB.Generic.Description% = N10FB, PCI\VEN_8086&DEV_10FB&SUBSYS_152D8975 %N154D.SFI.Dual.Description% = N10FB_NOSEC, PCI\VEN_8086&DEV_154D&SUBSYS_7B118086 %N10FB.SFI.NDC.Description% = N10FB_NDC, PCI\VEN_8086&DEV_10FB&SUBSYS_1F721028 %N10FB.SFI.ECNA.Description% = N10FB_ECNA, PCI\VEN_8086&DEV_10FB&SUBSYS_04708086 %N10FB.Generic.Description% = N10FB, PCI\VEN_8086&DEV_10FB %N10FC.Generic.Description% = N10FC, PCI\VEN_8086&DEV_10FC %N1529.Generic.Description% = N10FB, PCI\VEN_8086&DEV_1529 %N1557.Generic.Description% = N10FB_SP, PCI\VEN_8086&DEV_1557 %N151C.Copper.Dual.Description% = N151C, PCI\VEN_8086&DEV_151C&SUBSYS_A02C8086 %N151C.Copper.Dual.Description% = N151C, PCI\VEN_8086&DEV_151C&SUBSYS_A21C8086 %N151C.Copper.Dual.Description% = N151C, PCI\VEN_8086&DEV_151C&SUBSYS_A03C8086 %N151C.Copper.Dual.Sun.Description% = N151C, PCI\VEN_8086&DEV_151C&SUBSYS_7B13108E %N151C.Generic.Description% = N151C, PCI\VEN_8086&DEV_151C %N154A.SFI.Quad.Description% = N154A, PCI\VEN_8086&DEV_154A&SUBSYS_011A8086 %N154A.SFI.Quad.Description% = N154A, PCI\VEN_8086&DEV_154A&SUBSYS_011B8086 %N154A.SFI.Quad.Description% = N154A, PCI\VEN_8086&DEV_154A&SUBSYS_011C8086 %N1558.QSFP.Quad.Description% = N1558, PCI\VEN_8086&DEV_1558&SUBSYS_011A8086 %N1558.QSFP.Quad.Description% = N1558, PCI\VEN_8086&DEV_1558&SUBSYS_011B8086 [NO_DRV] Characteristics = 0x01 Include = machine.inf Needs = NO_DRV [NO_DRV.Services] Include = machine.inf Needs = NO_DRV.Services ; ------------------------------------------------------ ; Intel(R) 10 Gigabit X520 Server Adapters ; ------------------------------------------------------ [N10FB] Characteristics = 0x84 ; NCF_HAS_UI | NCF_PHYSICAL BusType = 5 ; PCI Port1FunctionNumber = 0 DelReg = Advanced.DelReg AddReg = Default.reg, RSS.reg, LLI.reg, DCB.reg, Uninstall.reg AddReg = FCoE.reg, IPSec.reg, Dualspeed.reg, Force10G.reg CopyFiles = CopyFiles, MessageDll.CopyFiles, Uninstall.CopyFiles *IfType = 6 ; IF_TYPE_ETHERNET_CSMACD *MediaType = 0 ; NdisMedium802_3 *PhysicalMediaType = 14 ; NdisPhysicalMedium802_3 [N10FB.Services] AddService = %ServiceName%, 0x12, Service, EventLog [N10FB.HW] Include = machine.inf Needs = PciSriovSupported, PciIoSpaceNotRequired AddReg = MSI.reg [N10FB.CoInstallers] AddReg = CoInstaller_AddReg, CoInK.reg CopyFiles = CoInstallerCopyFiles ; ------------------------------------------------------ ; Intel(R) 10 Gigabit X520-1 Server Adapters ; ------------------------------------------------------ [N10FB_SP] Characteristics = 0x84 ; NCF_HAS_UI | NCF_PHYSICAL BusType = 5 ; PCI DelReg = Advanced.DelReg AddReg = Default.reg, RSS.reg, LLI.reg, DCB.reg, Uninstall.reg AddReg = FCoE.reg, IPSec.reg, Dualspeed.reg, Force10G.reg CopyFiles = CopyFiles, MessageDll.CopyFiles, Uninstall.CopyFiles *IfType = 6 ; IF_TYPE_ETHERNET_CSMACD *MediaType = 0 ; NdisMedium802_3 *PhysicalMediaType = 14 ; NdisPhysicalMedium802_3 [N10FB_SP.Services] AddService = %ServiceName%, 0x12, Service, EventLog [N10FB_SP.HW] Include = machine.inf Needs = PciSriovSupported, PciIoSpaceNotRequired AddReg = MSI.reg [N10FB_SP.CoInstallers] AddReg = CoInstaller_AddReg, CoInK.reg CopyFiles = CoInstallerCopyFiles ; ------------------------------------------------------ ; Intel(R) 10 Gigabit X520 Server Adapters ; ------------------------------------------------------ [N10FB_NOSEC] Characteristics = 0x84 ; NCF_HAS_UI | NCF_PHYSICAL BusType = 5 ; PCI Port1FunctionNumber = 0 DelReg = Advanced.DelReg DelReg = IPSec.DelReg AddReg = Default.reg, RSS.reg, LLI.reg, DCB.reg, Uninstall.reg AddReg = NoIPSec.reg, FCoE.reg, Dualspeed.reg, Force10G.reg CopyFiles = CopyFiles, MessageDll.CopyFiles, Uninstall.CopyFiles *IfType = 6 ; IF_TYPE_ETHERNET_CSMACD *MediaType = 0 ; NdisMedium802_3 *PhysicalMediaType = 14 ; NdisPhysicalMedium802_3 [N10FB_NOSEC.Services] AddService = %ServiceName%, 0x12, Service, EventLog [N10FB_NOSEC.HW] Include = machine.inf Needs = PciSriovSupported, PciIoSpaceNotRequired AddReg = MSI.reg [N10FB_NOSEC.CoInstallers] AddReg = CoInstaller_AddReg, CoInK.reg CopyFiles = CoInstallerCopyFiles ; ------------------------------------------------------ ; Intel(R) 82599 Dual 10 Gigabit Network Connection ; ------------------------------------------------------ [N10FB_PM] Characteristics = 0x84 ; NCF_HAS_UI | NCF_PHYSICAL BusType = 5 ; PCI Port1FunctionNumber = 0 DelReg = Advanced.DelReg AddReg = Default.reg, RSS.reg, LLI.reg, DCB.reg, Uninstall.reg AddReg = FCoE.reg, IPSec.reg, Dualspeed.reg, Force10G.reg, Powermgmt.reg, PMEEnabled.reg, WakeOnSlot.reg CopyFiles = CopyFiles, MessageDll.CopyFiles, Uninstall.CopyFiles *IfType = 6 ; IF_TYPE_ETHERNET_CSMACD *MediaType = 0 ; NdisMedium802_3 *PhysicalMediaType = 14 ; NdisPhysicalMedium802_3 [N10FB_PM.Services] AddService = %ServiceName%, 0x12, Service, EventLog [N10FB_PM.HW] Include = machine.inf Needs = PciSriovSupported, PciIoSpaceNotRequired AddReg = MSI.reg [N10FB_PM.CoInstallers] AddReg = CoInstaller_AddReg, CoInKPM.reg CopyFiles = CoInstallerCopyFiles ; ------------------------------------------------------ ; Intel(R) Ethernet 10GSFP+ DP Embedded CNA X520-2 ; ------------------------------------------------------ [N10FB_ECNA] Characteristics = 0x84 ; NCF_HAS_UI | NCF_PHYSICAL BusType = 5 ; PCI Port1FunctionNumber = 0 DelReg = Advanced.DelReg AddReg = Default.reg, RSS.reg, LLI.reg, DCB.reg, Uninstall.reg AddReg = FCoE.reg, IPSec.reg, Dualspeed.reg, Force10G.reg, Powermgmt.reg, AdvPowermgmt.reg, PMEEnabled.reg CopyFiles = CopyFiles, MessageDll.CopyFiles, Uninstall.CopyFiles *IfType = 6 ; IF_TYPE_ETHERNET_CSMACD *MediaType = 0 ; NdisMedium802_3 *PhysicalMediaType = 14 ; NdisPhysicalMedium802_3 [N10FB_ECNA.Services] AddService = %ServiceName%, 0x12, Service, EventLog [N10FB_ECNA.HW] Include = machine.inf Needs = PciSriovSupported, PciIoSpaceNotRequired AddReg = MSI.reg [N10FB_ECNA.CoInstallers] AddReg = CoInstaller_AddReg, CoInK.reg CopyFiles = CoInstallerCopyFiles ; ------------------------------------------------------ ; Intel(R) Ethernet OCP Server Adapter X520-2 ; ------------------------------------------------------ [N10FB_OCP] Characteristics = 0x84 ; NCF_HAS_UI | NCF_PHYSICAL BusType = 5 ; PCI Port1FunctionNumber = 0 DelReg = Advanced.DelReg AddReg = Default.reg, RSS.reg, LLI.reg, NoDCB.reg, IPSec.reg, Dualspeed.reg, Force10G.reg, Powermgmt.reg, PMEEnabled.reg, WakeOnSlot.reg, Uninstall.reg CopyFiles = CopyFiles, MessageDll.CopyFiles, Uninstall.CopyFiles *IfType = 6 ; IF_TYPE_ETHERNET_CSMACD *MediaType = 0 ; NdisMedium802_3 *PhysicalMediaType = 14 ; NdisPhysicalMedium802_3 [N10FB_OCP.Services] AddService = %ServiceName%, 0x12, Service, EventLog [N10FB_OCP.HW] Include = machine.inf Needs = PciSriovSupported, PciIoSpaceNotRequired AddReg = MSI.reg [N10FB_OCP.CoInstallers] AddReg = CoInstaller_AddReg, CoInKPM.reg CopyFiles = CoInstallerCopyFiles ; ------------------------------------------------------ ; Intel(R) Ethernet OCP Server Adapter X520-1 ; ------------------------------------------------------ [N1557_OCP] Characteristics = 0x84 ; NCF_HAS_UI | NCF_PHYSICAL BusType = 5 ; PCI DelReg = Advanced.DelReg AddReg = Default.reg, RSS.reg, LLI.reg, NoDCB.reg, IPSec.reg, Dualspeed.reg, Force10G.reg, Powermgmt.reg, PMEEnabled.reg, WakeOnSlot.reg, Uninstall.reg CopyFiles = CopyFiles, MessageDll.CopyFiles, Uninstall.CopyFiles *IfType = 6 ; IF_TYPE_ETHERNET_CSMACD *MediaType = 0 ; NdisMedium802_3 *PhysicalMediaType = 14 ; NdisPhysicalMedium802_3 [N1557_OCP.Services] AddService = %ServiceName%, 0x12, Service, EventLog [N1557_OCP.HW] Include = machine.inf Needs = PciSriovSupported, PciIoSpaceNotRequired AddReg = MSI.reg [N1557_OCP.CoInstallers] AddReg = CoInstaller_AddReg, CoInK.reg CopyFiles = CoInstallerCopyFiles ; ------------------------------------------------------ ; Intel(R) 82599 10 Gigabit Dual Port Network Connection ; ------------------------------------------------------ [N10FC] Characteristics = 0x84 ; NCF_HAS_UI | NCF_PHYSICAL BusType = 5 ; PCI Port1FunctionNumber = 0 DelReg = Advanced.DelReg AddReg = Default.reg, RSS.reg, LLI.reg, DCB.reg, Uninstall.reg AddReg = FCoE.reg, IPSec.reg CopyFiles = CopyFiles, MessageDll.CopyFiles, Uninstall.CopyFiles *IfType = 6 ; IF_TYPE_ETHERNET_CSMACD *MediaType = 0 ; NdisMedium802_3 *PhysicalMediaType = 14 ; NdisPhysicalMedium802_3 [N10FC.Services] AddService = %ServiceName%, 0x12, Service, EventLog [N10FC.HW] Include = machine.inf Needs = PciSriovSupported, PciIoSpaceNotRequired AddReg = MSI.reg [N10FC.CoInstallers] AddReg = CoInstaller_AddReg, CoInK.reg CopyFiles = CoInstallerCopyFiles ; ----------------------------------------------- ; Intel(R) Ethernet Server Adapter X520-T1/T2 ; ----------------------------------------------- [N151C] Characteristics = 0x84 ; NCF_HAS_UI | NCF_PHYSICAL BusType = 5 ; PCI Port1FunctionNumber = 0 DelReg = Advanced.DelReg AddReg = Default.reg, RSS.reg, LLI.reg, DCB.reg, Uninstall.reg AddReg = NoFCoE.reg, IPSec.reg, Dualspeed.reg CopyFiles = CopyFiles, MessageDll.CopyFiles, Uninstall.CopyFiles *IfType = 6 ; IF_TYPE_ETHERNET_CSMACD *MediaType = 0 ; NdisMedium802_3 *PhysicalMediaType = 14 ; NdisPhysicalMedium802_3 [N151C.Services] AddService = %ServiceName%, 0x12, Service, EventLog [N151C.HW] Include = machine.inf Needs = PciSriovSupported, PciIoSpaceNotRequired AddReg = MSI.reg [N151C.CoInstallers] AddReg = CoInstaller_AddReg, CoInK.reg CopyFiles = CoInstallerCopyFiles ; ------------------------------------------------------ ; Intel(R) Ethernet Mezzanine Adapter X520-KX4 ; ------------------------------------------------------ [N10F7] Characteristics = 0x84 ; NCF_HAS_UI | NCF_PHYSICAL BusType = 5 ; PCI Port1FunctionNumber = 0 DelReg = Advanced.DelReg AddReg = Default.reg, RSS.reg, LLI.reg, DCB.reg, Uninstall.reg AddReg = FCoE.reg, IPSec.reg, Powermgmt.reg, PMEEnabled.reg CopyFiles = CopyFiles, MessageDll.CopyFiles, Uninstall.CopyFiles *IfType = 6 ; IF_TYPE_ETHERNET_CSMACD *MediaType = 0 ; NdisMedium802_3 *PhysicalMediaType = 14 ; NdisPhysicalMedium802_3 [N10F7.Services] AddService = %ServiceName%, 0x12, Service, EventLog [N10F7.HW] Include = machine.inf Needs = PciSriovSupported, PciIoSpaceNotRequired AddReg = MSI.reg [N10F7.CoInstallers] AddReg = CoInstaller_AddReg, CoInK.reg CopyFiles = CoInstallerCopyFiles ; ------------------------------------------------------ ; Intel(R) Ethernet 10G 2P X520-k bNDC ; ------------------------------------------------------ [N10F8_NDC] Characteristics = 0x84 ; NCF_HAS_UI | NCF_PHYSICAL BusType = 5 ; PCI Port1FunctionNumber = 0 DelReg = Advanced.DelReg DelReg = IPSec.DelReg AddReg = Default.reg, RSS.reg, LLI.reg, DCB.reg, Uninstall.reg AddReg = FCoE.reg, NoIPSec.reg, SmartSpeed.reg, Powermgmt.reg AddReg = AdvPowermgmt.reg CopyFiles = CopyFiles, MessageDll.CopyFiles, Uninstall.CopyFiles *IfType = 6 ; IF_TYPE_ETHERNET_CSMACD *MediaType = 0 ; NdisMedium802_3 *PhysicalMediaType = 14 ; NdisPhysicalMedium802_3 [N10F8_NDC.Services] AddService = %ServiceName%, 0x12, Service, EventLog [N10F8_NDC.HW] Include = machine.inf Needs = PciSriovSupported, PciIoSpaceNotRequired AddReg = MSI.reg [N10F8_NDC.CoInstallers] AddReg = CoInstaller_AddReg, CoInK.reg CopyFiles = CoInstallerCopyFiles ; ------------------------------------------------------ ;Intel(R) Ethernet 10G 4P X520/I350 rNDC ; ------------------------------------------------------ [N10FB_NDC] Characteristics = 0x84 ; NCF_HAS_UI | NCF_PHYSICAL BusType = 5 ; PCI Port1FunctionNumber = 0 DelReg = Advanced.DelReg DelReg = IPSec.DelReg AddReg = Default.reg, RSS.reg, LLI.reg, DCB.reg, Uninstall.reg AddReg = Powermgmt.reg, NoIPSec.reg, FCoE.reg, Dualspeed.reg, Force10G.reg CopyFiles = CopyFiles, MessageDll.CopyFiles, Uninstall.CopyFiles *IfType = 6 ; IF_TYPE_ETHERNET_CSMACD *MediaType = 0 ; NdisMedium802_3 *PhysicalMediaType = 14 ; NdisPhysicalMedium802_3 [N10FB_NDC.Services] AddService = %ServiceName%, 0x12, Service, EventLog [N10FB_NDC.HW] Include = machine.inf Needs = PciSriovSupported, PciIoSpaceNotRequired AddReg = MSI.reg [N10FB_NDC.CoInstallers] AddReg = CoInstaller_AddReg, CoInK.reg CopyFiles = CoInstallerCopyFiles ; ------------------------------------------------------ ; Intel(R) Ethernet X520 10GbE Dual Port KX4 Mezz ; ------------------------------------------------------ [N1514] Characteristics = 0x84 ; NCF_HAS_UI | NCF_PHYSICAL BusType = 5 ; PCI Port1FunctionNumber = 0 DelReg = Advanced.DelReg DelReg = IPSec.DelReg AddReg = Default.reg, RSS.reg, LLI.reg, DCB.reg, Uninstall.reg AddReg = FCoE.reg, NoIPSec.reg CopyFiles = CopyFiles, MessageDll.CopyFiles, Uninstall.CopyFiles *IfType = 6 ; IF_TYPE_ETHERNET_CSMACD *MediaType = 0 ; NdisMedium802_3 *PhysicalMediaType = 14 ; NdisPhysicalMedium802_3 [N1514.Services] AddService = %ServiceName%, 0x12, Service, EventLog [N1514.HW] Include = machine.inf Needs = PciSriovSupported, PciIoSpaceNotRequired AddReg = MSI.reg [N1514.CoInstallers] AddReg = CoInstaller_AddReg, CoInK.reg CopyFiles = CoInstallerCopyFiles ; ------------------------------------------------------ ; Intel(R) Ethernet X520 10GbE Dual Port KX4-KR Mezz ; ------------------------------------------------------ [N10F8_NoSec] Characteristics = 0x84 ; NCF_HAS_UI | NCF_PHYSICAL BusType = 5 ; PCI Port1FunctionNumber = 0 DelReg = Advanced.DelReg DelReg = IPSec.DelReg AddReg = Default.reg, RSS.reg, LLI.reg, DCB.reg, Uninstall.reg AddReg = FCoE.reg, NoIPSec.reg, SmartSpeed.reg CopyFiles = CopyFiles, MessageDll.CopyFiles, Uninstall.CopyFiles *IfType = 6 ; IF_TYPE_ETHERNET_CSMACD *MediaType = 0 ; NdisMedium802_3 *PhysicalMediaType = 14 ; NdisPhysicalMedium802_3 [N10F8_NoSec.Services] AddService = %ServiceName%, 0x12, Service, EventLog [N10F8_NoSec.HW] Include = machine.inf Needs = PciSriovSupported, PciIoSpaceNotRequired AddReg = MSI.reg [N10F8_NoSec.CoInstallers] AddReg = CoInstaller_AddReg, CoInK.reg CopyFiles = CoInstallerCopyFiles ; ------------------------------------------------------ ; Intel(R) 82599 10 Gigabit Dual Port Backplane Connection ; ------------------------------------------------------ [N10F8] Characteristics = 0x84 ; NCF_HAS_UI | NCF_PHYSICAL BusType = 5 ; PCI Port1FunctionNumber = 0 DelReg = Advanced.DelReg AddReg = Default.reg, RSS.reg, LLI.reg, DCB.reg, Uninstall.reg AddReg = FCoE.reg, IPSec.reg, Powermgmt.reg, SmartSpeed.reg CopyFiles = CopyFiles, MessageDll.CopyFiles, Uninstall.CopyFiles *IfType = 6 ; IF_TYPE_ETHERNET_CSMACD *MediaType = 0 ; NdisMedium802_3 *PhysicalMediaType = 14 ; NdisPhysicalMedium802_3 [N10F8.Services] AddService = %ServiceName%, 0x12, Service, EventLog [N10F8.HW] Include = machine.inf Needs = PciSriovSupported, PciIoSpaceNotRequired AddReg = MSI.reg [N10F8.CoInstallers] AddReg = CoInstaller_AddReg, CoInK.reg CopyFiles = CoInstallerCopyFiles ; ------------------------------------------------------ ; HP Ethernet 10Gb 2-port 560FLB Adapter ; ------------------------------------------------------ [HP10F8] Characteristics = 0x84 ; NCF_HAS_UI | NCF_PHYSICAL BusType = 5 ; PCI Port1FunctionNumber = 0 DelReg = Advanced.DelReg DelReg = IPSec.DelReg AddReg = Default.reg, RSS.reg, LLI.reg, NoDCB.reg, NoIPSec.reg, Uninstall.reg AddReg = Powermgmt.reg, SmartSpeed.reg CopyFiles = CopyFiles, MessageDll.CopyFiles, Uninstall.CopyFiles *IfType = 6 ; IF_TYPE_ETHERNET_CSMACD *MediaType = 0 ; NdisMedium802_3 *PhysicalMediaType = 14 ; NdisPhysicalMedium802_3 [HP10F8.Services] AddService = %ServiceName%, 0x12, Service, EventLog [HP10F8.HW] Include = machine.inf Needs = PciSriovSupported, PciIoSpaceNotRequired AddReg = MSI.reg [HP10F8.CoInstallers] AddReg = CoInstaller_AddReg, CoInK.reg CopyFiles = CoInstallerCopyFiles ; ------------------------------------------------------ ; HP Ethernet 10Gb 2-port 560FLR-SFP+ Adapter ; ------------------------------------------------------ [HP10FB_ALOM] Characteristics = 0x84 ; NCF_HAS_UI | NCF_PHYSICAL BusType = 5 ; PCI Port1FunctionNumber = 0 DelReg = Advanced.DelReg DelReg = IPSec.DelReg AddReg = Default.reg, RSS.reg, LLI.reg, NoDCB.reg, NoIPSec.reg, Uninstall.reg AddReg = Dualspeed.reg, Force10G.reg, Powermgmt.reg, WakeOnSlot.reg CopyFiles = CopyFiles, MessageDll.CopyFiles, Uninstall.CopyFiles *IfType = 6 ; IF_TYPE_ETHERNET_CSMACD *MediaType = 0 ; NdisMedium802_3 *PhysicalMediaType = 14 ; NdisPhysicalMedium802_3 [HP10FB_ALOM.Services] AddService = %ServiceName%, 0x12, Service, EventLog [HP10FB_ALOM.HW] Include = machine.inf Needs = PciSriovSupported, PciIoSpaceNotRequired AddReg = MSI.reg [HP10FB_ALOM.CoInstallers] AddReg = CoInstaller_AddReg, CoInKPM.reg CopyFiles = CoInstallerCopyFiles ; ------------------------------------------------------ ; HP Ethernet 10Gb 1-port P560FLR-SFP+ Adapter ; ------------------------------------------------------ [HP10FB_SP] Characteristics = 0x84 ; NCF_HAS_UI | NCF_PHYSICAL BusType = 5 ; PCI DelReg = Advanced.DelReg DelReg = IPSec.DelReg AddReg = Default.reg, RSS.reg, LLI.reg, NoDCB.reg, NoIPSec.reg, Uninstall.reg AddReg = Dualspeed.reg, Force10G.reg, Powermgmt.reg, WakeOnSlot.reg CopyFiles = CopyFiles, MessageDll.CopyFiles, Uninstall.CopyFiles *IfType = 6 ; IF_TYPE_ETHERNET_CSMACD *MediaType = 0 ; NdisMedium802_3 *PhysicalMediaType = 14 ; NdisPhysicalMedium802_3 [HP10FB_SP.Services] AddService = %ServiceName%, 0x12, Service, EventLog [HP10FB_SP.HW] Include = machine.inf Needs = PciSriovSupported, PciIoSpaceNotRequired AddReg = MSI.reg [HP10FB_SP.CoInstallers] AddReg = CoInstaller_AddReg, CoInK.reg CopyFiles = CoInstallerCopyFiles ; ------------------------------------------------------ ; HP Ethernet 10Gb 2-port 560SFP+ Adapter ; ------------------------------------------------------ [HP10FB] Characteristics = 0x84 ; NCF_HAS_UI | NCF_PHYSICAL BusType = 5 ; PCI Port1FunctionNumber = 0 DelReg = Advanced.DelReg DelReg = IPSec.DelReg AddReg = Default.reg, RSS.reg, LLI.reg, NoDCB.reg, NoIPSec.reg, Uninstall.reg AddReg = Dualspeed.reg, Force10G.reg CopyFiles = CopyFiles, MessageDll.CopyFiles, Uninstall.CopyFiles *IfType = 6 ; IF_TYPE_ETHERNET_CSMACD *MediaType = 0 ; NdisMedium802_3 *PhysicalMediaType = 14 ; NdisPhysicalMedium802_3 [HP10FB.Services] AddService = %ServiceName%, 0x12, Service, EventLog [HP10FB.HW] Include = machine.inf Needs = PciSriovSupported, PciIoSpaceNotRequired AddReg = MSI.reg [HP10FB.CoInstallers] AddReg = CoInstaller_AddReg, CoInK.reg CopyFiles = CoInstallerCopyFiles ; ------------------------------------------------------ ; Intel(R) Ethernet Converged Network Adapter X520-4 ; ------------------------------------------------------ [N154A] Characteristics = 0x84 ; NCF_HAS_UI | NCF_PHYSICAL BusType = 5 ; PCI Port1FunctionNumber = 0 DelReg = Advanced.DelReg AddReg = Default.reg, RSS.reg, LLI.reg, DCB.reg, Uninstall.reg AddReg = FCoE.reg, IPSec.reg, Dualspeed.reg, Force10G.reg CopyFiles = CopyFiles, MessageDll.CopyFiles, Uninstall.CopyFiles *IfType = 6 ; IF_TYPE_ETHERNET_CSMACD *MediaType = 0 ; NdisMedium802_3 *PhysicalMediaType = 14 ; NdisPhysicalMedium802_3 [N154A.Services] AddService = %ServiceName%, 0x12, Service, EventLog [N154A.HW] Include = machine.inf Needs = PciSriovSupported, PciIoSpaceNotRequired AddReg = MSI.reg [N154A.CoInstallers] AddReg = CoInstaller_AddReg, CoInKQP.reg CopyFiles = CoInstallerCopyFiles ; ------------------------------------------------------ ; Intel(R) Ethernet Converged Network Adapter X520-Q1 ; ------------------------------------------------------ [N1558] Characteristics = 0x84 ; NCF_HAS_UI | NCF_PHYSICAL BusType = 5 ; PCI Port1FunctionNumber = 0 DelReg = Advanced.DelReg AddReg = Default.reg, RSS.reg, LLI.reg, DCB.reg, Uninstall.reg AddReg = FCoE.reg, IPSec.reg, Forcespeed.reg CopyFiles = CopyFiles, MessageDll.CopyFiles, Uninstall.CopyFiles *IfType = 6 ; IF_TYPE_ETHERNET_CSMACD *MediaType = 0 ; NdisMedium802_3 *PhysicalMediaType = 14 ; NdisPhysicalMedium802_3 [N1558.Services] AddService = %ServiceName%, 0x12, Service, EventLog [N1558.HW] Include = machine.inf Needs = PciSriovSupported, PciIoSpaceNotRequired AddReg = MSI.reg [N1558.CoInstallers] AddReg = CoInstaller_AddReg, CoInKQP.reg CopyFiles = CoInstallerCopyFiles ;------------------------------------------------------------------------------- ; Registry Settings ;------------------------------------------------------------------------------- [Default.reg] HKR, Ndi\Interfaces, UpperRange, 0, "ndis5,illdpprot,IFCoE" HKR, Ndi\Interfaces, LowerRange, 0, "ethernet" HKR, Ndi, Service, 0, %ServiceName% ; *FlowControl HKR, Ndi\Params\*FlowControl, ParamDesc, 0, %FlowControl% HKR, Ndi\Params\*FlowControl, default, 0, "3" HKR, Ndi\Params\*FlowControl\Enum, "0", 0, %Disabled% HKR, Ndi\Params\*FlowControl\Enum, "1", 0, %FlowControl_TxOnly% HKR, Ndi\Params\*FlowControl\Enum, "2", 0, %FlowControl_RxOnly% HKR, Ndi\Params\*FlowControl\Enum, "3", 0, %FlowControl_Full% HKR, Ndi\Params\*FlowControl, type, 0, "enum" ; Force FlowControl on HKR,, *FlowControl, 0, "3" ; *TransmitBuffers HKR, Ndi\params\*TransmitBuffers, ParamDesc, 0, %TransmitBuffers% HKR, Ndi\params\*TransmitBuffers, default, 0, "512" HKR, Ndi\params\*TransmitBuffers, min, 0, "128" HKR, Ndi\params\*TransmitBuffers, max, 0, "16384" HKR, Ndi\params\*TransmitBuffers, step, 0, "64" HKR, Ndi\params\*TransmitBuffers, Base, 0, "10" HKR, Ndi\params\*TransmitBuffers, type, 0, "int" ; *ReceiveBuffers HKR, Ndi\params\*ReceiveBuffers, ParamDesc, 0, %ReceiveBuffers% HKR, Ndi\params\*ReceiveBuffers, default, 0, "512" HKR, Ndi\params\*ReceiveBuffers, min, 0, "128" HKR, Ndi\params\*ReceiveBuffers, max, 0, "4096" HKR, Ndi\params\*ReceiveBuffers, step, 0, "64" HKR, Ndi\params\*ReceiveBuffers, Base, 0, "10" HKR, Ndi\params\*ReceiveBuffers, type, 0, "int" ; Set MinHardwareOwnedPacketCount to 32 HKR,, MinHardwareOwnedPacketCount, 0, "32" ; *TCPChecksumOffloadIPv4 HKR, Ndi\Params\*TCPChecksumOffloadIPv4, ParamDesc, 0, %TCPChksumOffv4% HKR, Ndi\Params\*TCPChecksumOffloadIPv4, default, 0, "3" HKR, Ndi\Params\*TCPChecksumOffloadIPv4\Enum, "0", 0, %Disabled% HKR, Ndi\Params\*TCPChecksumOffloadIPv4\Enum, "1", 0, %ChksumOffTx% HKR, Ndi\Params\*TCPChecksumOffloadIPv4\Enum, "2", 0, %ChksumOffRx% HKR, Ndi\Params\*TCPChecksumOffloadIPv4\Enum, "3", 0, %ChksumOffTxRx% HKR, Ndi\Params\*TCPChecksumOffloadIPv4, type, 0, "enum" ; *TCPChecksumOffloadIPv6 HKR, Ndi\Params\*TCPChecksumOffloadIPv6, ParamDesc, 0, %TCPChksumOffv6% HKR, Ndi\Params\*TCPChecksumOffloadIPv6, default, 0, "3" HKR, Ndi\Params\*TCPChecksumOffloadIPv6\Enum, "0", 0, %Disabled% HKR, Ndi\Params\*TCPChecksumOffloadIPv6\Enum, "1", 0, %ChksumOffTx% HKR, Ndi\Params\*TCPChecksumOffloadIPv6\Enum, "2", 0, %ChksumOffRx% HKR, Ndi\Params\*TCPChecksumOffloadIPv6\Enum, "3", 0, %ChksumOffTxRx% HKR, Ndi\Params\*TCPChecksumOffloadIPv6, type, 0, "enum" ; *UDPChecksumOffloadIPv4 HKR, Ndi\Params\*UDPChecksumOffloadIPv4, ParamDesc, 0, %UDPChksumOffv4% HKR, Ndi\Params\*UDPChecksumOffloadIPv4, default, 0, "3" HKR, Ndi\Params\*UDPChecksumOffloadIPv4\Enum, "0", 0, %Disabled% HKR, Ndi\Params\*UDPChecksumOffloadIPv4\Enum, "1", 0, %ChksumOffTx% HKR, Ndi\Params\*UDPChecksumOffloadIPv4\Enum, "2", 0, %ChksumOffRx% HKR, Ndi\Params\*UDPChecksumOffloadIPv4\Enum, "3", 0, %ChksumOffTxRx% HKR, Ndi\Params\*UDPChecksumOffloadIPv4, type, 0, "enum" ; *UDPChecksumOffloadIPv6 HKR, Ndi\Params\*UDPChecksumOffloadIPv6, ParamDesc, 0, %UDPChksumOffv6% HKR, Ndi\Params\*UDPChecksumOffloadIPv6, default, 0, "3" HKR, Ndi\Params\*UDPChecksumOffloadIPv6\Enum, "0", 0, %Disabled% HKR, Ndi\Params\*UDPChecksumOffloadIPv6\Enum, "1", 0, %ChksumOffTx% HKR, Ndi\Params\*UDPChecksumOffloadIPv6\Enum, "2", 0, %ChksumOffRx% HKR, Ndi\Params\*UDPChecksumOffloadIPv6\Enum, "3", 0, %ChksumOffTxRx% HKR, Ndi\Params\*UDPChecksumOffloadIPv6, type, 0, "enum" ; *IPChecksumOffloadIPv4 HKR, Ndi\Params\*IPChecksumOffloadIPv4, ParamDesc, 0, %IPChksumOffv4% HKR, Ndi\Params\*IPChecksumOffloadIPv4, default, 0, "3" HKR, Ndi\Params\*IPChecksumOffloadIPv4\Enum, "0", 0, %Disabled% HKR, Ndi\Params\*IPChecksumOffloadIPv4\Enum, "1", 0, %ChksumOffTx% HKR, Ndi\Params\*IPChecksumOffloadIPv4\Enum, "2", 0, %ChksumOffRx% HKR, Ndi\Params\*IPChecksumOffloadIPv4\Enum, "3", 0, %ChksumOffTxRx% HKR, Ndi\Params\*IPChecksumOffloadIPv4, type, 0, "enum" ; Network Address HKR, Ndi\params\NetworkAddress, ParamDesc, 0, %LAA% HKR, Ndi\params\NetworkAddress, Default, 0, "" HKR, Ndi\params\NetworkAddress, type, 0, "edit" HKR, NDI\params\NetworkAddress, LimitText, 0, "12" HKR, NDI\params\NetworkAddress, UpperCase, 0, "1" HKR, NDI\params\NetworkAddress, optional, 0, "1" ;Log Link State Event HKR,Ndi\Params\LogLinkStateEvent, ParamDesc, 0, %LogLinkState% HKR,Ndi\Params\LogLinkStateEvent, Type, 0, "enum" HKR,Ndi\Params\LogLinkStateEvent, Default, 0, "51" HKR,Ndi\Params\LogLinkStateEvent\Enum, "51", 0, %Enabled% HKR,Ndi\Params\LogLinkStateEvent\Enum, "16", 0, %Disabled% HKR,, LogLinkStateEvent, 0, "51" ; Interrupt Throttle Rate HKR, Ndi\Params\ITR, ParamDesc, 0, %InterruptThrottleRate% HKR, Ndi\Params\ITR, default, 0, "65535" HKR, Ndi\Params\ITR\Enum, "65535", 0, %Adaptive% HKR, Ndi\Params\ITR\Enum, "2000", 0, %Extreme% HKR, Ndi\Params\ITR\Enum, "950", 0, %High% HKR, Ndi\Params\ITR\Enum, "488", 0, %Medium% HKR, Ndi\Params\ITR\Enum, "200", 0, %Low% HKR, Ndi\Params\ITR\Enum, "0", 0, %Off% HKR, Ndi\Params\ITR, type, 0, "enum" ; *PriorityVLANTag HKR, Ndi\Params\*PriorityVLANTag, ParamDesc, 0, %PriorityVLANTag2% HKR, Ndi\Params\*PriorityVLANTag, default, 0, "3" HKR, Ndi\Params\*PriorityVLANTag\Enum, "0", 0, %PriorityVlanDisabled2% HKR, Ndi\Params\*PriorityVLANTag\Enum, "1", 0, %PriorityEnabled2% HKR, Ndi\Params\*PriorityVLANTag\Enum, "2", 0, %VlanEnabled% HKR, Ndi\Params\*PriorityVLANTag\Enum, "3", 0, %PriorityVlanEnabled2% HKR, Ndi\Params\*PriorityVLANTag, type, 0, "enum" ; *InterruptModeration HKR, Ndi\Params\*InterruptModeration, ParamDesc, 0, %InterruptModeration% HKR, Ndi\Params\*InterruptModeration, default, 0, "1" HKR, Ndi\Params\*InterruptModeration\Enum, "0", 0, %Disabled% HKR, Ndi\Params\*InterruptModeration\Enum, "1", 0, %Enabled% HKR, Ndi\Params\*InterruptModeration, type, 0, "enum" ; *LsoV2IPv4 HKR, Ndi\Params\*LsoV2IPv4, ParamDesc, 0, %LsoV2IPv4% HKR, Ndi\Params\*LsoV2IPv4, default, 0, "1" HKR, Ndi\Params\*LsoV2IPv4\Enum, "0", 0, %Disabled% HKR, Ndi\Params\*LsoV2IPv4\Enum, "1", 0, %Enabled% HKR, Ndi\Params\*LsoV2IPv4, type, 0, "enum" ; *LsoV1IPv4 HKR,, *LsoV1IPv4, 0, "0" ; *LsoV2IPv6 HKR, Ndi\Params\*LsoV2IPv6, ParamDesc, 0, %LsoV2IPv6% HKR, Ndi\Params\*LsoV2IPv6, default, 0, "1" HKR, Ndi\Params\*LsoV2IPv6\Enum, "0", 0, %Disabled% HKR, Ndi\Params\*LsoV2IPv6\Enum, "1", 0, %Enabled% HKR, Ndi\Params\*LsoV2IPv6, type, 0, "enum" ; *JumboPacket HKR, Ndi\Params\*JumboPacket, ParamDesc, 0, %JumboPacket% HKR, Ndi\Params\*JumboPacket, default, 0, "1514" HKR, Ndi\Params\*JumboPacket\Enum, "1514", 0, %Disabled% HKR, Ndi\Params\*JumboPacket\Enum, "4088", 0, %Bytes4088% HKR, Ndi\Params\*JumboPacket\Enum, "9014", 0, %Bytes9014% HKR, Ndi\Params\*JumboPacket, type, 0, "enum" ; *RSCIPv4 HKR, Ndi\Params\*RSCIPv4, ParamDesc, 0, %RSCIPv4% HKR, Ndi\Params\*RSCIPv4, default, 0, "1" HKR, Ndi\Params\*RSCIPv4\Enum, "0", 0, %Disabled% HKR, Ndi\Params\*RSCIPv4\Enum, "1", 0, %Enabled% HKR, Ndi\Params\*RSCIPv4, type, 0, "enum" ; *QOS HKR, Ndi\Params\*QOS, ParamDesc, 0, %QOS% HKR, Ndi\Params\*QOS, default, 0, "0" HKR, Ndi\Params\*QOS, type, 0, "enum" HKR, Ndi\Params\*QOS\Enum, "0", 0, %Disabled% HKR, Ndi\Params\*QOS\Enum, "1", 0, %Enabled% ; *VMQ HKR, Ndi\Params\*VMQ, ParamDesc, 0, %VMQ% HKR, Ndi\Params\*VMQ, default, 0, "1" HKR, Ndi\Params\*VMQ, type, 0, "enum" HKR, Ndi\Params\*VMQ\Enum, "0", 0, %Disabled% HKR, Ndi\Params\*VMQ\Enum, "1", 0, %Enabled% HKR,, VMQSupported, 0, "1" ; *SRIOV HKR, Ndi\Params\*SRIOV, ParamDesc, 0, %Sriov% HKR, Ndi\Params\*SRIOV, default, 0, "1" HKR, Ndi\Params\*SRIOV, type, 0, "enum" HKR, Ndi\Params\*SRIOV\Enum, "0", 0, %Disabled% HKR, Ndi\Params\*SRIOV\Enum, "1", 0, %Enabled% ; SRIOV Default switch configuration HKR, NicSwitches\0,*Flags, 0x00010001, 0x06 HKR, NicSwitches\0,*SwitchType, 0x00010001, 1 HKR, NicSwitches\0,*SwitchId, 0x00010001, 0 HKR, NicSwitches\0,*SwitchName, 0, "DefaultSwitchName" HKR, NicSwitches\0,*NumVFs, 0x00010001, 62 HKR, NicSwitches\0,*NumVPorts, 0x00010001, 64 HKR, NicSwitches\0,*NumQueuePairsForDefaultVPort, 0x00010001, 1 HKR, NicSwitches\0,*NumQueuePairsForNonDefaultVPorts, 0x00010001, 63 ; Miscellanous defaults HKR,, MulticastFilterType, 0, "0" HKR,, VlanFiltering, 0, "0" [FCoE.reg] HKR,, EnableFcoeOffload, 2, "1" ; FcoeStartingNumaNode HKR, PROSetNdi\Params\FCoEStartingNumaNodeId, ParamDesc, 0, %FCoEStartingNumaNodeId% HKR, PROSetNdi\params\FCoEStartingNumaNodeId, default, 0, "0" HKR, PROSetNdi\params\FCoEStartingNumaNodeId, min, 0, "0" HKR, PROSetNdi\params\FCoEStartingNumaNodeId, max, 0, "15" HKR, PROSetNdi\params\FCoEStartingNumaNodeId, step, 0, "1" HKR, PROSetNdi\params\FCoEStartingNumaNodeId, Base, 0, "10" HKR, PROSetNdi\params\FCoEStartingNumaNodeId, type, 0, "int" HKR,, FCoEStartingNumaNodeId, 2, "0" ; FcoeNumaNodeCount HKR, PROSetNdi\Params\FCoENumaNodeCount, ParamDesc, 0, %FCoENumaNodeCount% HKR, PROSetNdi\params\FCoENumaNodeCount, default, 0, "1" HKR, PROSetNdi\params\FCoENumaNodeCount, min, 0, "1" HKR, PROSetNdi\params\FCoENumaNodeCount, max, 0, "7" HKR, PROSetNdi\params\FCoENumaNodeCount, step, 0, "1" HKR, PROSetNdi\params\FCoENumaNodeCount, Base, 0, "10" HKR, PROSetNdi\params\FCoENumaNodeCount, type, 0, "int" HKR,, FCoENumaNodeCount, 2, "1" ; FCoEStartingRSSCoreNumber HKR, PROSetNdi\Params\FCoEStartingRSSCoreNumber, ParamDesc, 0, %FCoEStartingRSSCoreNumber% HKR, PROSetNdi\params\FCoEStartingRSSCoreNumber, default, 0, "0" HKR, PROSetNdi\params\FCoEStartingRSSCoreNumber, min, 0, "0" HKR, PROSetNdi\params\FCoEStartingRSSCoreNumber, max, 0, "15" HKR, PROSetNdi\params\FCoEStartingRSSCoreNumber, step, 0, "1" HKR, PROSetNdi\params\FCoEStartingRSSCoreNumber, Base, 0, "10" HKR, PROSetNdi\params\FCoEStartingRSSCoreNumber, type, 0, "int" HKR,, FCoEStartingRSSCoreNumber, 2, "0" [NoFCoE.reg] HKR, Ndi\Interfaces, UpperRange, 0, "ndis5,illdpprot" HKR,, EnableFcoeOffload, 0, "0" [Dualspeed.reg] HKR, Ndi\params\*SpeedDuplex, ParamDesc, 0, %SpeedDuplex% HKR, Ndi\params\*SpeedDuplex, default, 0, "0" HKR, Ndi\params\*SpeedDuplex, type, 0, "enum" HKR, Ndi\params\*SpeedDuplex\enum, "0", 0, %AutoNegotiation% HKR, Ndi\params\*SpeedDuplex\enum, "6", 0, %1000Mb_Full_Duplex% [Force10G.reg] HKR, Ndi\params\*SpeedDuplex\enum, "7", 0, %10Gb_Full_Duplex% [Forcespeed.reg] HKR, Ndi\params\*SpeedDuplex, ParamDesc, 0, %SpeedDuplex% HKR, Ndi\params\*SpeedDuplex, default, 0, "7" HKR, Ndi\params\*SpeedDuplex, type, 0, "enum" HKR, Ndi\params\*SpeedDuplex\enum, "6", 0, %1000Mb_Full_Duplex% HKR, Ndi\params\*SpeedDuplex\enum, "7", 0, %10Gb_Full_Duplex% [RSS.reg] ; NumRssQueues HKR, Ndi\Params\*NumRssQueues, ParamDesc, 0, %NumRssQueues2% HKR, Ndi\Params\*NumRssQueues, default, 0, "8" HKR, Ndi\Params\*NumRssQueues, type, 0, "enum" HKR, Ndi\Params\*NumRssQueues\Enum, "1", 0, %1queue% HKR, Ndi\Params\*NumRssQueues\Enum, "2", 0, %2queues% HKR, Ndi\Params\*NumRssQueues\Enum, "4", 0, %4queues% HKR, Ndi\Params\*NumRssQueues\Enum, "8", 0, %8queues% HKR, Ndi\Params\*NumRssQueues\Enum, "16", 0, %16queues% ; *RSSProfile HKR, Ndi\Params\*RSSProfile, ParamDesc, 0, %RSSProfile% HKR, Ndi\Params\*RSSProfile, default, 0, "1" HKR, Ndi\Params\*RSSProfile, type, 0, "enum" HKR, Ndi\Params\*RSSProfile\Enum, "1", 0, %Closest_Processor% HKR, Ndi\Params\*RSSProfile\Enum, "2", 0, %Closest_Processor_Static% HKR, Ndi\Params\*RSSProfile\Enum, "3", 0, %NUMA_Scaling% HKR, Ndi\Params\*RSSProfile\Enum, "4", 0, %NUMA_Scaling_Static% HKR, Ndi\Params\*RSSProfile\Enum, "5", 0, %Conservative_Scaling% ; *RSS HKR, Ndi\Params\*RSS, ParamDesc, 0, %RSS% HKR, Ndi\Params\*RSS, default, 0, "1" HKR, Ndi\Params\*RSS, type, 0, "enum" HKR, Ndi\Params\*RSS\Enum, "0", 0, %Disabled% HKR, Ndi\Params\*RSS\Enum, "1", 0, %Enabled% ; *RssBaseProcNumber HKR, Ndi\params\*RssBaseProcNumber, ParamDesc, 0, %RssBaseProcNumber% HKR, Ndi\params\*RssBaseProcNumber, default, 0, "0" HKR, Ndi\params\*RssBaseProcNumber, min, 0, "0" HKR, Ndi\params\*RssBaseProcNumber, max, 0, "63" HKR, Ndi\params\*RssBaseProcNumber, step, 0, "1" HKR, Ndi\params\*RssBaseProcNumber, Optional, 0, "0" HKR, Ndi\params\*RssBaseProcNumber, type, 0, "int" ; *NumaNodeId HKR, Ndi\params\*NumaNodeId, ParamDesc, 0, %NumaNodeId% HKR, Ndi\params\*NumaNodeId, default, 0, "65535" HKR, Ndi\params\*NumaNodeId, type, 0, "enum" HKR, Ndi\params\*NumaNodeId\Enum, "65535", 0, %default% HKR, Ndi\params\*NumaNodeId\Enum, "0", 0, %node0% HKR, Ndi\params\*NumaNodeId\Enum, "1", 0, %node1% HKR, Ndi\params\*NumaNodeId\Enum, "2", 0, %node2% HKR, Ndi\params\*NumaNodeId\Enum, "3", 0, %node3% HKR, Ndi\params\*NumaNodeId\Enum, "4", 0, %node4% HKR, Ndi\params\*NumaNodeId\Enum, "5", 0, %node5% HKR, Ndi\params\*NumaNodeId\Enum, "6", 0, %node6% HKR, Ndi\params\*NumaNodeId\Enum, "7", 0, %node7% ; *MaxRssProcessors HKR, Ndi\params\*MaxRssProcessors, ParamDesc, 0, %MaxRssProcessors% HKR, Ndi\params\*MaxRssProcessors, default, 0, "16" HKR, Ndi\params\*MaxRssProcessors, type, 0, "enum" HKR, Ndi\params\*MaxRssProcessors\Enum, "1", 0, "1" HKR, Ndi\params\*MaxRssProcessors\Enum, "2", 0, "2" HKR, Ndi\params\*MaxRssProcessors\Enum, "4", 0, "4" HKR, Ndi\params\*MaxRssProcessors\Enum, "8", 0, "8" HKR, Ndi\params\*MaxRssProcessors\Enum, "16", 0, "16" [LLI.reg] HKR, PROSetNdi\Params\EnableLLI, ParamDesc, 0, %EnableLLI% HKR, PROSetNdi\Params\EnableLLI, default, 0, "0" HKR, PROSetNdi\Params\EnableLLI, type, 0, "enum" HKR, PROSetNdi\Params\EnableLLI\Enum, "0", 0, %Disabled% HKR, PROSetNdi\Params\EnableLLI\Enum, "1", 0, %LLIPortBased% HKR, PROSetNdi\Params\EnableLLI\Enum, "2", 0, %LLIPSHBased% HKR,, EnableLLI, 2, "0" HKR, PROSetNdi\Params\LLIPorts, ParamDesc, 0, %LLIPorts% HKR, PROSetNdi\Params\LLIPorts, default, 0, "" HKR, PROSetNdi\Params\LLIPorts, type, 0, "edit" HKR, PROSetNdi\Params\LLIPorts, UpperCase, 0, "1" HKR, PROSetNdi\Params\LLIPorts, optional, 0, "1" HKR, PROSetNdi\Params\LLIPorts, multi_string, 0, "1" HKR,, LLIPorts, 0x00010002, "" [NoDCB.reg] HKR, Ndi\Interfaces, UpperRange, 0, "ndis5" HKR,, EnableFcoeOffload, 0, "0" [DCB.reg] HKR, DcbCfg, DcbPfcAdvertise, 2, "1" HKR, DcbCfg, DcbPfcEnable, 2, "1" HKR, DcbCfg, DcbPfcWilling, 2, "1" HKR, DcbCfg, DcbPgAdvertise, 2, "1" HKR, DcbCfg, DcbPgEnable, 2, "1" HKR, DcbCfg, DcbPgWilling, 2, "1" HKR, DcbCfg, Bw0DetailTx, 2, "Bandwidth Group 0" HKR, DcbCfg, Bw0DetailRx, 2, "Bandwidth Group 0" HKR, DcbCfg, Bw0PercentageRx, 2, "13" HKR, DcbCfg, Bw0PercentageTx, 2, "13" HKR, DcbCfg, Bw1DetailTx, 2, "Bandwidth Group 1" HKR, DcbCfg, Bw1DetailRx, 2, "Bandwidth Group 1" HKR, DcbCfg, Bw1PercentageRx, 2, "13" HKR, DcbCfg, Bw1PercentageTx, 2, "13" HKR, DcbCfg, Bw2DetailTx, 2, "Bandwidth Group 2" HKR, DcbCfg, Bw2DetailRx, 2, "Bandwidth Group 2" HKR, DcbCfg, Bw2PercentageRx, 2, "13" HKR, DcbCfg, Bw2PercentageTx, 2, "13" HKR, DcbCfg, Bw3DetailTx, 2, "Bandwidth Group 3" HKR, DcbCfg, Bw3DetailRx, 2, "Bandwidth Group 3" HKR, DcbCfg, Bw3PercentageRx, 2, "13" HKR, DcbCfg, Bw3PercentageTx, 2, "13" HKR, DcbCfg, Bw4DetailTx, 2, "Bandwidth Group 4" HKR, DcbCfg, Bw4DetailRx, 2, "Bandwidth Group 4" HKR, DcbCfg, Bw4PercentageRx, 2, "12" HKR, DcbCfg, Bw4PercentageTx, 2, "12" HKR, DcbCfg, Bw5DetailTx, 2, "Bandwidth Group 5" HKR, DcbCfg, Bw5DetailRx, 2, "Bandwidth Group 5" HKR, DcbCfg, Bw5PercentageRx, 2, "12" HKR, DcbCfg, Bw5PercentageTx, 2, "12" HKR, DcbCfg, Bw6DetailTx, 2, "Bandwidth Group 6" HKR, DcbCfg, Bw6DetailRx, 2, "Bandwidth Group 6" HKR, DcbCfg, Bw6PercentageRx, 2, "12" HKR, DcbCfg, Bw6PercentageTx, 2, "12" HKR, DcbCfg, Bw7DetailTx, 2, "Bandwidth Group 7" HKR, DcbCfg, Bw7DetailRx, 2, "Bandwidth Group 7" HKR, DcbCfg, Bw7PercentageRx, 2, "12" HKR, DcbCfg, Bw7PercentageTx, 2, "12" HKR, DcbCfg\St0Config, DcbAppData, 0x00000003 , "00" HKR, DcbCfg\St0Config, DcbAppAdvertise, 2, "0" HKR, DcbCfg\St0Config, DcbAppEnable, 2, "1" HKR, DcbCfg\St0Config, DcbAppWilling, 2, "1" HKR, DcbCfg\St0Config, DcbLLinkAdvertise, 2, "1" HKR, DcbCfg\St0Config, DcbLLinkEnable, 2, "1" HKR, DcbCfg\St0Config, DcbLLinkWilling, 2, "1" HKR, DcbCfg\St1Config, DcbAppData, 0x00000003 , "00" HKR, DcbCfg\St1Config, DcbAppAdvertise, 2, "0" HKR, DcbCfg\St1Config, DcbAppEnable, 2, "1" HKR, DcbCfg\St1Config, DcbAppWilling, 2, "1" HKR, DcbCfg\Tc0Config, Pfc, 2, "1" HKR, DcbCfg\Tc0Config\Rx, BwID, 2, "0" HKR, DcbCfg\Tc0Config\Rx, BwPercentage, 2, "100" HKR, DcbCfg\Tc0Config\Rx, UptoTc, 2, "1" HKR, DcbCfg\Tc0Config\Rx, StrictPriority, 2, "0" HKR, DcbCfg\Tc0Config\Tx, BwID, 2, "0" HKR, DcbCfg\Tc0Config\Tx, BwPercentage, 2, "100" HKR, DcbCfg\Tc0Config\Tx, UptoTc, 2, "1" HKR, DcbCfg\Tc0Config\Tx, StrictPriority, 2, "0" HKR, DcbCfg\Tc1Config, Pfc, 2, "1" HKR, DcbCfg\Tc1Config\Rx, BwID, 2, "1" HKR, DcbCfg\Tc1Config\Rx, BwPercentage, 2, "100" HKR, DcbCfg\Tc1Config\Rx, UptoTc, 2, "2" HKR, DcbCfg\Tc1Config\Rx, StrictPriority, 2, "0" HKR, DcbCfg\Tc1Config\Tx, BwID, 2, "1" HKR, DcbCfg\Tc1Config\Tx, BwPercentage, 2, "100" HKR, DcbCfg\Tc1Config\Tx, UptoTc, 2, "2" HKR, DcbCfg\Tc1Config\Tx, StrictPriority, 2, "0" HKR, DcbCfg\Tc2Config, Pfc, 2, "1" HKR, DcbCfg\Tc2Config\Rx, BwID, 2, "2" HKR, DcbCfg\Tc2Config\Rx, BwPercentage, 2, "100" HKR, DcbCfg\Tc2Config\Rx, UptoTc, 2, "4" HKR, DcbCfg\Tc2Config\Rx, StrictPriority, 2, "0" HKR, DcbCfg\Tc2Config\Tx, BwID, 2, "2" HKR, DcbCfg\Tc2Config\Tx, BwPercentage, 2, "100" HKR, DcbCfg\Tc2Config\Tx, UptoTc, 2, "4" HKR, DcbCfg\Tc2Config\Tx, StrictPriority, 2, "0" HKR, DcbCfg\Tc3Config, Pfc, 2, "1" HKR, DcbCfg\Tc3Config\Rx, BwID, 2, "3" HKR, DcbCfg\Tc3Config\Rx, BwPercentage, 2, "100" HKR, DcbCfg\Tc3Config\Rx, UptoTc, 2, "8" HKR, DcbCfg\Tc3Config\Rx, StrictPriority, 2, "0" HKR, DcbCfg\Tc3Config\Tx, BwID, 2, "3" HKR, DcbCfg\Tc3Config\Tx, BwPercentage, 2, "100" HKR, DcbCfg\Tc3Config\Tx, UptoTc, 2, "8" HKR, DcbCfg\Tc3Config\Tx, StrictPriority, 2, "0" HKR, DcbCfg\Tc4Config, Pfc, 2, "1" HKR, DcbCfg\Tc4Config\Rx, BwID, 2, "4" HKR, DcbCfg\Tc4Config\Rx, BwPercentage, 2, "100" HKR, DcbCfg\Tc4Config\Rx, UptoTc, 2, "16" HKR, DcbCfg\Tc4Config\Rx, StrictPriority, 2, "0" HKR, DcbCfg\Tc4Config\Tx, BwID, 2, "4" HKR, DcbCfg\Tc4Config\Tx, BwPercentage, 2, "100" HKR, DcbCfg\Tc4Config\Tx, UptoTc, 2, "16" HKR, DcbCfg\Tc4Config\Tx, StrictPriority, 2, "0" HKR, DcbCfg\Tc5Config, Pfc, 2, "1" HKR, DcbCfg\Tc5Config\Rx, BwID, 2, "5" HKR, DcbCfg\Tc5Config\Rx, BwPercentage, 2, "100" HKR, DcbCfg\Tc5Config\Rx, UptoTc, 2, "32" HKR, DcbCfg\Tc5Config\Rx, StrictPriority, 2, "0" HKR, DcbCfg\Tc5Config\Tx, BwID, 2, "5" HKR, DcbCfg\Tc5Config\Tx, BwPercentage, 2, "100" HKR, DcbCfg\Tc5Config\Tx, UptoTc, 2, "32" HKR, DcbCfg\Tc5Config\Tx, StrictPriority, 2, "0" HKR, DcbCfg\Tc6Config, Pfc, 2, "1" HKR, DcbCfg\Tc6Config\Rx, BwID, 2, "6" HKR, DcbCfg\Tc6Config\Rx, BwPercentage, 2, "100" HKR, DcbCfg\Tc6Config\Rx, UptoTc, 2, "64" HKR, DcbCfg\Tc6Config\Rx, StrictPriority, 2, "0" HKR, DcbCfg\Tc6Config\Tx, BwID, 2, "6" HKR, DcbCfg\Tc6Config\Tx, BwPercentage, 2, "100" HKR, DcbCfg\Tc6Config\Tx, UptoTc, 2, "64" HKR, DcbCfg\Tc6Config\Tx, StrictPriority, 2, "0" HKR, DcbCfg\Tc7Config, Pfc, 2, "1" HKR, DcbCfg\Tc7Config\Rx, BwID, 2, "7" HKR, DcbCfg\Tc7Config\Rx, BwPercentage, 2, "100" HKR, DcbCfg\Tc7Config\Rx, UptoTc, 2, "128" HKR, DcbCfg\Tc7Config\Rx, StrictPriority, 2, "0" HKR, DcbCfg\Tc7Config\Tx, BwID, 2, "7" HKR, DcbCfg\Tc7Config\Tx, BwPercentage, 2, "100" HKR, DcbCfg\Tc7Config\Tx, UptoTc, 2, "128" HKR, DcbCfg\Tc7Config\Tx, StrictPriority, 2, "0" [MSI.reg] HKR, "Interrupt Management", 0x00000010 HKR, "Interrupt Management\MessageSignaledInterruptProperties", 0x00000010 HKR, "Interrupt Management\MessageSignaledInterruptProperties", MSISupported, 0x00010001, 1 HKR, "Interrupt Management\MessageSignaledInterruptProperties", MessageNumberLimit, 0x00010001, 18 [IPSec.reg] ; IPSec capabilities HKR, Ndi\Params\*IPsecOffloadV2, ParamDesc, 0, %IPsecOffloadV2% HKR, Ndi\Params\*IPsecOffloadV2, default, 0, "3" HKR, Ndi\Params\*IPsecOffloadV2\Enum, "0", 0, %Disabled% HKR, Ndi\Params\*IPsecOffloadV2\Enum, "1", 0, %IPsecAH% HKR, Ndi\Params\*IPsecOffloadV2\Enum, "2", 0, %IPsecESP% HKR, Ndi\Params\*IPsecOffloadV2\Enum, "3", 0, %IPsecAHESP% HKR, Ndi\Params\*IPsecOffloadV2, type, 0, "enum" [NoIPSec.reg] HKR,, IPSecurity, 0, "0" [Powermgmt.reg] ; EnablePME HKR,Ndi\Params\EnablePME, ParamDesc, 0, %Enable_PME% HKR,Ndi\Params\EnablePME, Type, 0, "enum" HKR,Ndi\Params\EnablePME, Default, 0, "0" HKR,Ndi\Params\EnablePME\Enum, "1", 0, %Enabled% HKR,Ndi\Params\EnablePME\Enum, "0", 0, %Disabled% [AdvPowermgmt.reg] ; *WakeOnPattern HKR,Ndi\Params\*WakeOnPattern, ParamDesc, 0, %WakeOnPattern% HKR,Ndi\Params\*WakeOnPattern, Type, 0, "enum" HKR,Ndi\Params\*WakeOnPattern, Default, 0, "1" HKR,Ndi\Params\*WakeOnPattern\Enum, "1", 0, %Enabled% HKR,Ndi\Params\*WakeOnPattern\Enum, "0", 0, %Disabled% ; *WakeOnMagicPacket HKR,Ndi\Params\*WakeOnMagicPacket, ParamDesc, 0, %WakeOnMagicPacket% HKR,Ndi\Params\*WakeOnMagicPacket, Type, 0, "enum" HKR,Ndi\Params\*WakeOnMagicPacket, Default, 0, "1" HKR,Ndi\Params\*WakeOnMagicPacket\Enum, "1", 0, %Enabled% HKR,Ndi\Params\*WakeOnMagicPacket\Enum, "0", 0, %Disabled% [PMEEnabled.reg] HKR,, EnablePME, 0, "1" [WakeOnSlot.reg] HKR,, WakeOnSlot, 0, 0 [SmartSpeed.reg] HKR,Ndi\Params\SmartSpeed, ParamDesc, 0, %SmartSpeed% HKR,Ndi\Params\SmartSpeed, Type, 0, "enum" HKR,Ndi\Params\SmartSpeed, Default, 0, "0" HKR,Ndi\Params\SmartSpeed\Enum, "0", 0, %Enabled% HKR,Ndi\Params\SmartSpeed\Enum, "2", 0, %Disabled% [Advanced.DelReg] HKR, Ndi\Params HKR, PROSetNdi\Params HKR, PROSetNdi\NdiExt HKR,, EnableDca [IPSec.DelReg] HKR,, *IPsecOffloadV2 [AddEventLog] HKR,, EventMessageFile, 0x00020000, %EventLogMessageDllPath% HKR,, TypesSupported, 0x00010001, 7 ;----------------------------------------------------------------------------- ; Uninstall parameters ;----------------------------------------------------------------------------- [Uninstall.reg] HKLM,Software\Intel\Prounstl\SupportedDevices\8086, 10A6, 0, "10A6" HKLM,Software\Intel\Prounstl\SupportedDevices\8086, 10F9, 0, "10F9" HKLM,Software\Intel\Prounstl\SupportedDevices\8086, 151C, 0, "151C" HKLM,Software\Intel\Prounstl\SupportedDevices\8086, 10FB, 0, "10FB" HKLM,Software\Intel\Prounstl\SupportedDevices\8086, 10FC, 0, "10FC" HKLM,Software\Intel\Prounstl\SupportedDevices\8086, 1529, 0, "1529" HKLM,Software\Intel\Prounstl\SupportedDevices\8086, 1557, 0, "1557" HKLM,Software\Intel\Prounstl\SupportedDevices\8086, 10F8, 0, "10F8" HKLM,Software\Intel\Prounstl\SupportedDevices\8086, 152A, 0, "152A" HKLM,Software\Intel\Prounstl\SupportedDevices\8086, 154D, 0, "154D" HKLM,Software\Intel\Prounstl\SupportedDevices\8086, 10F7, 0, "10F7" HKLM,Software\Intel\Prounstl\SupportedDevices\8086, 1507, 0, "1507" HKLM,Software\Intel\Prounstl\SupportedDevices\8086, 1514, 0, "1514" HKLM,Software\Intel\Prounstl\SupportedDevices\8086, 1517, 0, "1517" HKLM,Software\Intel\Prounstl\SupportedDevices\8086, 154A, 0, "154A" HKLM,Software\Intel\Prounstl\SupportedDevices\8086, 1558, 0, "1558" HKLM,Software\Intel\Prounstl\Dins, ixn64x64.din, 0, "8259x.Uninstall" HKLM,Software\Intel\Prounstl\Services, %ServiceName%, 0, ixn64x64.sys ;----------------------------------------------------------------------------- ; Driver "service" installation settings ;----------------------------------------------------------------------------- [Service] DisplayName = %Service.Displayname% ServiceType = 1 ;%SERVICE_KERNEL_DRIVER% StartType = 3 ;%SERVICE_DEMAND_START% ErrorControl = 1 ;%SERVICE_ERROR_NORMAL% ServiceBinary = %12%\ixn64x64.sys LoadOrderGroup = NDIS ;----------------------------------------------------------------------------- ; Event Log settings ;----------------------------------------------------------------------------- [EventLog] AddReg = AddEventLog ;----------------------------------------------------------------------------- ; Coinstaller installation ;----------------------------------------------------------------------------- [CoInstallerCopyFiles] NicCo36.dll,,,0x00000010 ;don't overwrite NicInIXN.dll [CoInstaller_AddReg] HKR,, CoInstallers32, 0x00010000, "NicCo36.dll,NicCoInstallerEntry" HKR,, NicCoPlugins, 0x00010000, "NicInIXN.dll,NicCoInstallerEntry" [CoInK.reg] HKR,, CoInstallFlag, 0x00010001, 0x00201000 [CoInKPM.reg] HKR,, CoInstallFlag, 0x00010001, 0x00201400 [CoInKQP.reg] HKR,, CoInstallFlag, 0x00010001, 0x00201800 [MessageDll.CopyFiles] ixnmsg.dll,,,2 [Uninstall.CopyFiles] ixn64x64.din,,,2 [CopyFiles] ixn64x64.sys,,,2 ;----------------------------------------------------------------------------- ; DestinationDirs ;----------------------------------------------------------------------------- [DestinationDirs] CopyFiles = 12 DefaultDestDir = 11 Uninstall.CopyFiles = 11 CoInstallerCopyFiles = 11 MessageDll.CopyFiles = 11 [SourceDisksNames] 1 = %DiskName%,,, ;----------------------------------------------------------------------------- ; SourceDisksFiles ;----------------------------------------------------------------------------- [SourceDisksFiles] ixn64x64.sys = 1 ixn64x64.din = 1 ixnmsg.dll = 1 NicCo36.dll = 1 NicInIXN.dll = 1 [Strings] EnableLLI = "Low Latency Interrupts" LLIPorts = "Low Latency Interrupt Ports" LLIPortBased = "Port-Based" LLIPSHBased = "PSH Flag-Based" InterruptModeration = "Interrupt Moderation" InterruptThrottleRate = "Interrupt Moderation Rate" Adaptive = "Adaptive" Extreme = "Extreme" High = "High" Medium = "Medium" Low = "Low" IPChksumOffv4 = "IPv4 Checksum Offload" TCPChksumOffv4 = "TCP Checksum Offload (IPv4)" UDPChksumOffv4 = "UDP Checksum Offload (IPv4)" LsoV2IPv4 = "Large Send Offload V2 (IPv4)" TCPChksumOffv6 = "TCP Checksum Offload (IPv6)" UDPChksumOffv6 = "UDP Checksum Offload (IPv6)" LsoV2IPv6 = "Large Send Offload V2 (IPv6)" ChksumOffTxRx = "Rx & Tx Enabled" ChksumOffTx = "Tx Enabled" ChksumOffRx = "Rx Enabled" TransmitBuffers = "Transmit Buffers" ReceiveBuffers = "Receive Buffers" RSS = "Receive Side Scaling" NumRssQueues2 = "Maximum Number of RSS Queues" RSSProfile = "RSS load balancing profile" Closest_Processor = "ClosestProcessor" Closest_Processor_Static = "ClosestProcessorStatic" NUMA_Scaling = "NUMAScaling" NUMA_Scaling_Static = "NUMAScalingStatic" Conservative_Scaling = "ConservativeScaling" RssBaseProcNumber = "Starting RSS CPU" MaxRssProcessors = "Maximum Number of RSS Processors" NumaNodeId = "Preferred NUMA node" default = "System Default" node0 = "Node 0" node1 = "Node 1" node2 = "Node 2" node3 = "Node 3" node4 = "Node 4" node5 = "Node 5" node6 = "Node 6" node7 = "Node 7" 1queue = "1 Queue" 2queues = "2 Queues" 4queues = "4 Queues" 8queues = "8 Queues" 16queues = "16 Queues" IPsecOffloadV2 = "IPsec Offload" IPsecAH = "Auth Header Enabled" IPsecESP = "ESP Enabled" IPSecAHESP = "Auth Header & ESP Enabled" FCoEStartingNumaNodeId = "FCoE Starting NUMA Node" FCoENumaNodeCount = "FCoE NUMA Node Count" FCoEStartingRSSCoreNumber = "FCoE Starting RSS Core Number" FlowControl = "Flow Control" FlowControl_RxOnly = "Rx Enabled" FlowControl_TxOnly = "Tx Enabled" FlowControl_Full = "Rx & Tx Enabled" PriorityVLANTag2 = "Packet Priority & VLAN" PriorityVlanDisabled2 = "Packet Priority & VLAN Disabled" PriorityEnabled2 = "Packet Priority Enabled" PriorityVlanEnabled2 = "Packet Priority & VLAN Enabled" VlanEnabled = "VLAN Enabled" SpeedDuplex = "Speed & Duplex" AutoNegotiation = "Auto Negotiation" 1000Mb_Full_Duplex = "1.0 Gbps Full Duplex" 10Gb_Full_Duplex = "10 Gbps Full Duplex" Off = "Off" Enabled = "Enabled" Disabled = "Disabled" Bytes4088 = "4088 Bytes" Bytes9014 = "9014 Bytes" LAA = "Locally Administered Address" JumboPacket = "Jumbo Packet" RSCIPv4 = "Recv Segment Coalescing (IPv4)" LogLinkState = "Log Link State Event" Enable_PME = "Enable PME" WakeOnMagicPacket = "Wake on Magic Packet" WakeOnPattern = "Wake on Pattern Match" VMQ = "Virtual Machine Queues" SRIOV = "SR-IOV" QOS = "NDIS QOS" SmartSpeed = "Smart Speed" ServiceName = "ixgbn" Intel = "Intel" EventLogMessageDllPath = "%SystemRoot%\System32\netevent.dll;%SystemRoot%\System32\drivers\ixn64x64.sys" DiskName = "Intel(R) PRO/10GbE Driver Disk" Service.Displayname = "Intel(R) PRO/10GbE PCIe-N Network Connection Driver" ;----------------------------------------------------------------------------- ; Device Description Strings ;----------------------------------------------------------------------------- O10A6.DeviceDesc = "Intel(R) 82599 Multi-Function Network Device" N10F7.Generic.Description = "Intel(R) 10 Gigabit BR KX4 Dual Port Network Connection" N10F8.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Backplane Connection" N152A.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Backplane Connection with FCoE" N10F7.KX4.Dual.Description = "Intel(R) Ethernet Mezzanine Adapter X520-KX4-2" N1514.KX4.Dual.Description = "Intel(R) Ethernet X520 10GbE Dual Port KX4 Mezz" N10F8.KX4.KR.Dual.Description = "Intel(R) Ethernet X520 10GbE Dual Port KX4-KR Mezz" N10F8.KR.NDC.Description = "Intel(R) Ethernet 10G 2P X520-k bNDC" N1507.SFI.Dual.Description = "Intel(R) Ethernet ExpressModule X520-P2" N10F7.KX4.FEM.Description = "Sun Dual 10GbE PCIe 2.0 FEM" N1517.KR.Dual.Description = "Cisco UCS CNA M61KR-I Intel Converged Network Adapter" N154D.SFI.Dual.Description = "Intel(R) Ethernet 10G 2P X520 Adapter" HP10F8.KR.BLOM.Description = "HP Ethernet 10Gb 2-port 560FLB Adapter" HP10F8.KR.Dual.Description = "HP Ethernet 10Gb 2-port 560M Adapter" HP10FB.SFI.ALOM.Description = "HP Ethernet 10Gb 2-port 560FLR-SFP+ Adapter" HP10FB.SFI.ALOM.SP.Description = "HP Ethernet 10Gb 1-port P560FLR-SFP+ Adapter" HP10FB.SFI.LOM.Description = "HP Ethernet 10Gb 2-port 562i Adapter" N10FB.OCP.DP.Generic.Description = "Intel(R) Ethernet OCP Server Adapter X520-2" N1557.OCP.SP.Generic.Description = "Intel(R) Ethernet OCP Server Adapter X520-1" N10FB.SFI.FLEXLOM.Description = "Lenovo ThinkServer X520-2 AnyFabric" HP10FB.SFI.Dual.Description = "HP Ethernet 10Gb 2-port 560SFP+ Adapter" N10F9.Generic.Description = "Intel(R) 82599 10 Gigabit CX4 Dual Port Network Connection" N10FB.SFI.Single.Description = "Intel(R) Ethernet Server Adapter X520-1" N10FB.SFI.Dual.Description = "Intel(R) Ethernet Server Adapter X520-2" N10FB.CopperDA.Dual.Description = "Intel(R) Ethernet Server Adapter X520-DA2" N10FB.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Network Connection" N10FB.SFI.NDC.Description = "Intel(R) Ethernet 10G 4P X520/I350 rNDC" N10FB.SFI.ECNA.Description = "Intel(R) Ethernet 10GSFP+ DP Embedded CNA X520-2" N10FC.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Network Connection" N1529.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Network Connection with FCoE" N1557.Generic.Description = "Intel(R) 82599 10 Gigabit Network Connection" N151C.Copper.Dual.Description = "Intel(R) Ethernet Server Adapter X520-T2" N151C.Copper.Dual.Sun.Description = "Sun Dual 10GBASE-T LP" N151C.Generic.Description = "Intel(R) 82599 10 Gigabit TN Network Connection" N154A.SFI.Quad.Description = "Intel(R) Ethernet Converged Network Adapter X520-4" N1558.QSFP.Quad.Description = "Intel(R) Ethernet Converged Network Adapter X520-Q1" ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- [Strings.0804] ; Chinese (Simplified) EnableLLI ="µÍÑÓ³ÙÖжÏ" LLIPorts ="µÍÑÓ³ÙÖж϶˿Ú" LLIPortBased ="»ùÓڶ˿ڵÄ" LLIPSHBased ="»ùÓÚ PSH ±ê¼ÇµÄ" InterruptModeration ="ÖжϽÚÁ÷" InterruptThrottleRate ="ÖжϽÚÁ÷ÂÊ" Adaptive ="ÊÊÓ¦ÐÔ" Extreme ="¼«Öµ" High ="¸ß" Medium ="ÖÐ" Low ="µÍ" IPChksumOffv4 ="IPv4 УÑéºÍ·ÖÔØ´«Êä" TCPChksumOffv4 ="TCP УÑéºÍ·ÖÔØ´«Êä (IPv4)" UDPChksumOffv4 ="UDP УÑéºÍ·ÖÔØ´«Êä (IPv4)" LsoV2IPv4 ="´óÐÍ·¢ËÍ·ÖÔØ V2 (IPv4)" TCPChksumOffv6 ="TCP УÑéºÍ·ÖÔØ´«Êä (IPv6)" UDPChksumOffv6 ="UDP УÑéºÍ·ÖÔØ´«Êä (IPv6)" LsoV2IPv6 ="´óÐÍ·¢ËÍ·ÖÔØ V2 (IPv6)" ChksumOffTxRx ="ÒÑÆôÓà Rx ºÍ Tx" ChksumOffTx ="ÒÑÆôÓà Tx" ChksumOffRx ="ÒÑÆôÓà Rx" TransmitBuffers ="´«Ê仺³åÇø" ReceiveBuffers ="½ÓÊÕ»º³åÇø" RSS ="½ÓÊÕ·½µ÷Õû" NumRssQueues2 ="RSS ¶ÓÁеÄ×î´óÊýÄ¿" RSSProfile ="RSS ¸ºÔØƽºâÅäÖÃʽ" Closest_Processor ="×î½üµÄ´¦ÀíÆ÷" Closest_Processor_Static ="×î½üµÄ´¦ÀíÆ÷£¨¾²Ì¬£©" NUMA_Scaling ="NUMA µ÷Õû" NUMA_Scaling_Static ="NUMA µ÷Õû£¨¾²Ì¬£©" Conservative_Scaling ="±£Êص÷Õû" RssBaseProcNumber ="Æô¶¯ RSS CPU" MaxRssProcessors ="RSS ´¦ÀíÆ÷µÄ×î´óÊýÄ¿" NumaNodeId ="Ê×Ñ¡µÄ NUMA ½Úµã" default ="ϵͳĬÈÏÖµ" node0 ="½Úµã 0" node1 ="½Úµã 1" node2 ="½Úµã 2" node3 ="½Úµã 3" node4 ="½Úµã 4" node5 ="½Úµã 5" node6 ="½Úµã 6" node7 ="½Úµã 7" 1queue ="1 ¸ö¶ÓÁÐ" 2queues ="2 ¸ö¶ÓÁÐ" 4queues ="4 ¸ö¶ÓÁÐ" 8queues ="8 ¸ö¶ÓÁÐ" 16queues ="16 ¸ö¶ÓÁÐ" IPsecOffloadV2 ="IPsec ·ÖÔØ" IPsecAH ="ÒÑÆôÓà Auth Header" IPsecESP ="ÒÑÆôÓà ESP" IPSecAHESP ="ÒÑÆôÓà Auth Header ºÍ ESP" FCoEStartingNumaNodeId ="FCoE Æðʼ NUMA ½Úµã" FCoENumaNodeCount ="FCoE NUMA ½Úµã¼ÆÊý" FCoEStartingRSSCoreNumber ="FCoE Æðʼ RSS ºËÐÄÊý" FlowControl ="Á÷Á¿¿ØÖÆ" FlowControl_RxOnly ="ÒÑÆôÓà Rx" FlowControl_TxOnly ="ÒÑÆôÓà Tx" FlowControl_Full ="ÒÑÆôÓà Rx ºÍ Tx" PriorityVLANTag2 ="Êý¾Ý°üÓÅÏȼ¶ºÍ VLAN" PriorityVlanDisabled2 ="ÒѽûÓÃÊý¾Ý°üÓÅÏȼ¶ºÍ VLAN" PriorityEnabled2 ="ÒÑÆôÓÃÊý¾Ý°üÓÅÏȼ¶" PriorityVlanEnabled2 ="ÒÑÆôÓÃÊý¾Ý°üÓÅÏȼ¶ºÍ VLAN" VlanEnabled ="ÒÑÆôÓà VLAN" SpeedDuplex ="ËٶȺÍË«¹¤" AutoNegotiation ="×Ô¶¯Ð­ÉÌ" 1000Mb_Full_Duplex ="1.0 Gbps È«Ë«¹¤" 10Gb_Full_Duplex ="10 Gbps È«Ë«¹¤" Off ="¹Ø±Õ" Enabled ="ÆôÓÃ" Disabled ="½ûÓÃ" Bytes4088 ="4088 ×Ö½Ú" Bytes9014 ="9014 ×Ö½Ú" LAA ="±¾µØ¹ÜÀíµØÖ·" JumboPacket ="¾ÞÖ¡Êý¾Ý°ü" RSCIPv4 ="½ÓÊÕƬ¶Ï½áºÏ (IPv4)" LogLinkState ="¼Ç¼Á´½Ó״̬ʼþ" Enable_PME ="ÆôÓà PME" WakeOnMagicPacket ="»½ÐÑħ°ü" WakeOnPattern ="»½ÐÑģʽƥÅä" VMQ ="ÐéÄâ»ú¶ÓÁÐ" SRIOV ="SR-IOV" QOS ="NDIS QOS" SmartSpeed ="ÖÇÄÜËÙ¶È" ServiceName = "ixgbn" Intel = "Intel" EventLogMessageDllPath = "%SystemRoot%\System32\netevent.dll;%SystemRoot%\System32\ixnmsg.dll" DiskName = "Intel(R) PRO/10GbE Driver Disk" Service.Displayname = "Intel(R) PRO/10GbE PCIe-N Network Connection Driver" ;----------------------------------------------------------------------------- ; Device Description Strings ;----------------------------------------------------------------------------- O10A6.DeviceDesc = "Intel(R) 82599 Multi-Function Network Device" N10F7.Generic.Description = "Intel(R) 10 Gigabit BR KX4 Dual Port Network Connection" N10F8.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Backplane Connection" N152A.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Backplane Connection with FCoE" N10F7.KX4.Dual.Description = "Intel(R) Ethernet Mezzanine Adapter X520-KX4-2" N1514.KX4.Dual.Description = "Intel(R) Ethernet X520 10GbE Dual Port KX4 Mezz" N10F8.KX4.KR.Dual.Description = "Intel(R) Ethernet X520 10GbE Dual Port KX4-KR Mezz" N10F8.KR.NDC.Description = "Intel(R) Ethernet 10G 2P X520-k bNDC" N1507.SFI.Dual.Description = "Intel(R) Ethernet ExpressModule X520-P2" N10F7.KX4.FEM.Description = "Sun Dual 10GbE PCIe 2.0 FEM" N1517.KR.Dual.Description = "Cisco UCS CNA M61KR-I Intel Converged Network Adapter" N154D.SFI.Dual.Description = "Intel(R) Ethernet 10G 2P X520 Adapter" HP10F8.KR.BLOM.Description = "HP Ethernet 10Gb 2-port 560FLB Adapter" HP10F8.KR.Dual.Description = "HP Ethernet 10Gb 2-port 560M Adapter" HP10FB.SFI.ALOM.Description = "HP Ethernet 10Gb 2-port 560FLR-SFP+ Adapter" HP10FB.SFI.ALOM.SP.Description = "HP Ethernet 10Gb 1-port P560FLR-SFP+ Adapter" HP10FB.SFI.LOM.Description = "HP Ethernet 10Gb 2-port 562i Adapter" N10FB.OCP.DP.Generic.Description = "Intel(R) Ethernet OCP Server Adapter X520-2" N1557.OCP.SP.Generic.Description = "Intel(R) Ethernet OCP Server Adapter X520-1" N10FB.SFI.FLEXLOM.Description = "Lenovo ThinkServer X520-2 AnyFabric" HP10FB.SFI.Dual.Description = "HP Ethernet 10Gb 2-port 560SFP+ Adapter" N10F9.Generic.Description = "Intel(R) 82599 10 Gigabit CX4 Dual Port Network Connection" N10FB.SFI.Single.Description = "Intel(R) Ethernet Server Adapter X520-1" N10FB.SFI.Dual.Description = "Intel(R) Ethernet Server Adapter X520-2" N10FB.CopperDA.Dual.Description = "Intel(R) Ethernet Server Adapter X520-DA2" N10FB.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Network Connection" N10FB.SFI.NDC.Description = "Intel(R) Ethernet 10G 4P X520/I350 rNDC" N10FB.SFI.ECNA.Description = "Intel(R) Ethernet 10GSFP+ DP Embedded CNA X520-2" N10FC.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Network Connection" N1529.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Network Connection with FCoE" N1557.Generic.Description = "Intel(R) 82599 10 Gigabit Network Connection" N151C.Copper.Dual.Description = "Intel(R) Ethernet Server Adapter X520-T2" N151C.Copper.Dual.Sun.Description = "Sun Dual 10GBASE-T LP" N151C.Generic.Description = "Intel(R) 82599 10 Gigabit TN Network Connection" N154A.SFI.Quad.Description = "Intel(R) Ethernet Converged Network Adapter X520-4" N1558.QSFP.Quad.Description = "Intel(R) Ethernet Converged Network Adapter X520-Q1" ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- [Strings.0404] ; Chinese (Traditional) EnableLLI ="§C©µ¿ð§ÃÂ_" LLIPorts ="§C©µ¿ð§ÃÂ_³s±µ°ð" LLIPortBased ="³s±µ°ð¬°°ò¦" LLIPSHBased ="PSH ºX¸¹¬°°ò¦" InterruptModeration ="§ÃÂ_½Õ¸`" InterruptThrottleRate ="§ÃÂ_¸`¬y»Ö³t²v" Adaptive ="½Õ¾ã©Ê" Extreme ="·¥°ª" High ="°ª" Medium ="¤¤" Low ="§C" IPChksumOffv4 ="IPv4 Àˬd­È¨ø¸ü" TCPChksumOffv4 ="TCP Àˬd­È¨ø¸ü (IPv4)" UDPChksumOffv4 ="UDP Àˬd­È¨ø¸ü (IPv4)" LsoV2IPv4 ="¤j¶q¶Ç°e¨ø¸ü V2 (IPv4)" TCPChksumOffv6 ="TCP Àˬd­È¨ø¸ü (IPv6)" UDPChksumOffv6 ="UDP Àˬd­È¨ø¸ü (IPv6)" LsoV2IPv6 ="¤j¶q¶Ç°e¨ø¸ü V2 (IPv6)" ChksumOffTxRx ="Rx »P Tx ¤w±Ò¥Î" ChksumOffTx ="Tx ¤w±Ò¥Î" ChksumOffRx ="Rx ¤w±Ò¥Î" TransmitBuffers ="¶Ç¿é½w½Ä°Ï" ReceiveBuffers ="±µ¦¬½w½Ä°Ï" RSS ="±µ¦¬ºÝ½Õ¾ã¤ñ²v" NumRssQueues2 ="RSS ¦î¦Cªº³Ì¤j¼Æ¥Ø" RSSProfile ="RSS ¸ü¶q¥­¿Å³]©wÀÉ" Closest_Processor ="³Ì±µªñªº³B²z¾¹" Closest_Processor_Static ="³Ì±µªñªº³B²z¾¹¡]ÀRºA¡^" NUMA_Scaling ="NUMA ½Õ¾ã" NUMA_Scaling_Static ="NUMA ½Õ¾ã¡]ÀRºA¡^" Conservative_Scaling ="«O¦u½Õ¾ã" RssBaseProcNumber ="±Ò°Ê RSS CPU" MaxRssProcessors ="RSS ³B²z¾¹ªº³Ì¤j¼Æ¥Ø" NumaNodeId ="°¾¦nªº NUMA ¸`ÂI" default ="¨t²Î¹w³]­È" node0 ="¸`ÂI 0" node1 ="¸`ÂI 1" node2 ="¸`ÂI 2" node3 ="¸`ÂI 3" node4 ="¸`ÂI 4" node5 ="¸`ÂI 5" node6 ="¸`ÂI 6" node7 ="¸`ÂI 7" 1queue ="¤@­Ó¦î¦C" 2queues ="¨â­Ó¦î¦C" 4queues ="¥|­Ó¦î¦C" 8queues ="¤K­Ó¦î¦C" 16queues ="¤Q¤»­Ó¦î¦C" IPsecOffloadV2 ="IPsec ¨ø¸ü" IPsecAH ="¼ÐÃD»{ÃÒ (Auth Header) ¤w±Ò¥Î" IPsecESP ="ESP ¤w±Ò¥Î" IPSecAHESP ="¼ÐÃD»{ÃÒ (Auth Header) »P ESP ¤w±Ò¥Î" FCoEStartingNumaNodeId ="FCoE ±Ò°Ê NUMA ¸`ÂI" FCoENumaNodeCount ="FCoE NUMA ¸`ÂI¼Æ" FCoEStartingRSSCoreNumber ="FCoE ±Ò°Ê RSS ®Ö¤ß¸¹½X" FlowControl ="¬y¶q±±¨î" FlowControl_RxOnly ="Rx ¤w±Ò¥Î" FlowControl_TxOnly ="Tx ¤w±Ò¥Î" FlowControl_Full ="Rx »P Tx ¤w±Ò¥Î" PriorityVLANTag2 ="®M¥óÀu¥ý¶¶§Ç»P VLAN" PriorityVlanDisabled2 ="®M¥óÀu¥ý¶¶§Ç»P VLAN ¤w°±¥Î" PriorityEnabled2 ="®M¥óÀu¥ý¶¶§Ç¤w±Ò¥Î" PriorityVlanEnabled2 ="®M¥óÀu¥ý¶¶§Ç»P VLAN ¤w±Ò¥Î" VlanEnabled ="VLAN ¤w±Ò¥Î" SpeedDuplex ="³t«×»PÂù¤u" AutoNegotiation ="¦Û°Ê¥æ¯A" 1000Mb_Full_Duplex ="1.0 Gbps ¥þÂù¤u" 10Gb_Full_Duplex ="10 Gbps ¥þÂù¤u" Off ="Ãö³¬" Enabled ="±Ò¥Î" Disabled ="°±¥Î" Bytes4088 ="4088 ¦ì¤¸²Õ" Bytes9014 ="9014 ¦ì¤¸²Õ" LAA ="¥»¦aºÞ²z¦ì§}" JumboPacket ="¶W¤j«¬«Ê¥]" RSCIPv4 ="±µ¦¬°Ï¬qµ²¦X (IPv4)" LogLinkState ="µn¿ý³sµ²ª¬ºA¨Æ¥ó" Enable_PME ="±Ò¥Î PME" WakeOnMagicPacket ="³ê¿ô¯«©_«Ê¥]" WakeOnPattern ="¦b®æ¦¡¤Ç°t³ê¿ô" VMQ ="µêÀÀ¾÷¾¹¦î¦C" SRIOV ="SR-IOV" QOS ="NDIS QOS" SmartSpeed ="¦Û°Ê¤Á´«³t«×" ServiceName = "ixgbn" Intel = "Intel" EventLogMessageDllPath = "%SystemRoot%\System32\netevent.dll;%SystemRoot%\System32\ixnmsg.dll" DiskName = "Intel(R) PRO/10GbE Driver Disk" Service.Displayname = "Intel(R) PRO/10GbE PCIe-N Network Connection Driver" ;----------------------------------------------------------------------------- ; Device Description Strings ;----------------------------------------------------------------------------- O10A6.DeviceDesc = "Intel(R) 82599 Multi-Function Network Device" N10F7.Generic.Description = "Intel(R) 10 Gigabit BR KX4 Dual Port Network Connection" N10F8.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Backplane Connection" N152A.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Backplane Connection with FCoE" N10F7.KX4.Dual.Description = "Intel(R) Ethernet Mezzanine Adapter X520-KX4-2" N1514.KX4.Dual.Description = "Intel(R) Ethernet X520 10GbE Dual Port KX4 Mezz" N10F8.KX4.KR.Dual.Description = "Intel(R) Ethernet X520 10GbE Dual Port KX4-KR Mezz" N10F8.KR.NDC.Description = "Intel(R) Ethernet 10G 2P X520-k bNDC" N1507.SFI.Dual.Description = "Intel(R) Ethernet ExpressModule X520-P2" N10F7.KX4.FEM.Description = "Sun Dual 10GbE PCIe 2.0 FEM" N1517.KR.Dual.Description = "Cisco UCS CNA M61KR-I Intel Converged Network Adapter" N154D.SFI.Dual.Description = "Intel(R) Ethernet 10G 2P X520 Adapter" HP10F8.KR.BLOM.Description = "HP Ethernet 10Gb 2-port 560FLB Adapter" HP10F8.KR.Dual.Description = "HP Ethernet 10Gb 2-port 560M Adapter" HP10FB.SFI.ALOM.Description = "HP Ethernet 10Gb 2-port 560FLR-SFP+ Adapter" HP10FB.SFI.ALOM.SP.Description = "HP Ethernet 10Gb 1-port P560FLR-SFP+ Adapter" HP10FB.SFI.LOM.Description = "HP Ethernet 10Gb 2-port 562i Adapter" N10FB.OCP.DP.Generic.Description = "Intel(R) Ethernet OCP Server Adapter X520-2" N1557.OCP.SP.Generic.Description = "Intel(R) Ethernet OCP Server Adapter X520-1" N10FB.SFI.FLEXLOM.Description = "Lenovo ThinkServer X520-2 AnyFabric" HP10FB.SFI.Dual.Description = "HP Ethernet 10Gb 2-port 560SFP+ Adapter" N10F9.Generic.Description = "Intel(R) 82599 10 Gigabit CX4 Dual Port Network Connection" N10FB.SFI.Single.Description = "Intel(R) Ethernet Server Adapter X520-1" N10FB.SFI.Dual.Description = "Intel(R) Ethernet Server Adapter X520-2" N10FB.CopperDA.Dual.Description = "Intel(R) Ethernet Server Adapter X520-DA2" N10FB.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Network Connection" N10FB.SFI.NDC.Description = "Intel(R) Ethernet 10G 4P X520/I350 rNDC" N10FB.SFI.ECNA.Description = "Intel(R) Ethernet 10GSFP+ DP Embedded CNA X520-2" N10FC.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Network Connection" N1529.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Network Connection with FCoE" N1557.Generic.Description = "Intel(R) 82599 10 Gigabit Network Connection" N151C.Copper.Dual.Description = "Intel(R) Ethernet Server Adapter X520-T2" N151C.Copper.Dual.Sun.Description = "Sun Dual 10GBASE-T LP" N151C.Generic.Description = "Intel(R) 82599 10 Gigabit TN Network Connection" N154A.SFI.Quad.Description = "Intel(R) Ethernet Converged Network Adapter X520-4" N1558.QSFP.Quad.Description = "Intel(R) Ethernet Converged Network Adapter X520-Q1" ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- [Strings.0407] ; German (Germany) EnableLLI ="Low Latency Interrupts (LLIs)" LLIPorts ="LLI-Anschlüsse" LLIPortBased ="Anschlussbasiert" LLIPSHBased ="PSH markierungsbasiert" InterruptModeration ="Interrupt-Drosselung" InterruptThrottleRate ="Interrupt-Drosselungsrate" Adaptive ="Adaptiv" Extreme ="Extrem" High ="Hoch" Medium ="Mittel" Low ="Niedrig" IPChksumOffv4 ="IPv4-Prüfsummen abladen" TCPChksumOffv4 ="TCP-Prüfsummen abladen (IPv4)" UDPChksumOffv4 ="UDP-Prüfsummen abladen (IPv4)" LsoV2IPv4 ="Large-Send-Offload V2 (IPv4)" TCPChksumOffv6 ="TCP-Prüfsummen abladen (IPv6)" UDPChksumOffv6 ="UDP-Prüfsummen abladen (IPv6)" LsoV2IPv6 ="Large-Send-Offload V2 (IPv6)" ChksumOffTxRx ="Rx und Tx aktiviert" ChksumOffTx ="Tx aktiviert" ChksumOffRx ="Rx aktiviert" TransmitBuffers ="Übertragungspuffer" ReceiveBuffers ="Empfangspuffer" RSS ="RSS (Empfangsseitige Skalierung)" NumRssQueues2 ="Max. Anzahl RSS-Warteschlangen" RSSProfile ="RSS-Load-Balancing-Profil" Closest_Processor ="Nächster Prozessor" Closest_Processor_Static ="Nächster Prozessor (statisch)" NUMA_Scaling ="NUMA-Skalierung" NUMA_Scaling_Static ="NUMA-Skalierung (statisch)" Conservative_Scaling ="Konservative Skalierung" RssBaseProcNumber ="Start-RSS-CPU" MaxRssProcessors ="Max. Anzahl RSS-CPUs" NumaNodeId ="Bevorzugter NUMA-Knoten" default ="Systemstandard" node0 ="Knoten 0" node1 ="Knoten 1" node2 ="Knoten 2" node3 ="Knoten 3" node4 ="Knoten 4" node5 ="Knoten 5" node6 ="Knoten 6" node7 ="Knoten 7" 1queue ="1 Warteschlange" 2queues ="2 Warteschlangen" 4queues ="4 Warteschlangen" 8queues ="8 Warteschlangen" 16queues ="16 Warteschlangen" IPsecOffloadV2 ="IPsec abladen" IPsecAH ="Auth.-Header aktiviert" IPsecESP ="ESP aktiviert" IPSecAHESP ="Auth.-Header und ESP aktiviert" FCoEStartingNumaNodeId ="FCoE – Start-NUMA-Knoten" FCoENumaNodeCount ="FCoE – Anzahl NUMA-Knoten" FCoEStartingRSSCoreNumber ="FCoE – Start-RSS-Core-Zahl" FlowControl ="Flusssteuerung" FlowControl_RxOnly ="Rx aktiviert" FlowControl_TxOnly ="Tx aktiviert" FlowControl_Full ="Rx und Tx aktiviert" PriorityVLANTag2 ="Paketpriorität und VLAN" PriorityVlanDisabled2 ="Paketpriorität und VLAN deaktiviert" PriorityEnabled2 ="Paketpriorität aktiviert" PriorityVlanEnabled2 ="Paketpriorität und VLAN aktiviert" VlanEnabled ="VLAN aktiviert" SpeedDuplex ="Geschwindigkeit & Duplex" AutoNegotiation ="Automatische Aushandlung" 1000Mb_Full_Duplex ="1,0 Gbit/s Vollduplex" 10Gb_Full_Duplex ="10 Gbit/s Vollduplex" Off ="Aus" Enabled ="Aktiviert" Disabled ="Deaktiviert" Bytes4088 ="4088 Byte" Bytes9014 ="9014 Byte" LAA ="Lokal verwaltete Adresse" JumboPacket ="Jumbo Packet" RSCIPv4 ="Recv. Segment Coalescing (IPv4)" LogLinkState ="Verbindungsereignis protokollieren" Enable_PME ="PME aktivieren" WakeOnMagicPacket ="Akt. über Magic Packet" WakeOnPattern ="Akt. bei Musterübereinstimmung" VMQ ="Virtuelle Maschinen-Warteschlangen" SRIOV ="SR-IOV" QOS ="NDIS-QoS" SmartSpeed ="Smart Speed" ServiceName = "ixgbn" Intel = "Intel" EventLogMessageDllPath = "%SystemRoot%\System32\netevent.dll;%SystemRoot%\System32\ixnmsg.dll" DiskName = "Intel(R) PRO/10GbE Driver Disk" Service.Displayname = "Intel(R) PRO/10GbE PCIe-N Network Connection Driver" ;----------------------------------------------------------------------------- ; Device Description Strings ;----------------------------------------------------------------------------- O10A6.DeviceDesc = "Intel(R) 82599 Multi-Function Network Device" N10F7.Generic.Description = "Intel(R) 10 Gigabit BR KX4 Dual Port Network Connection" N10F8.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Backplane Connection" N152A.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Backplane Connection with FCoE" N10F7.KX4.Dual.Description = "Intel(R) Ethernet Mezzanine Adapter X520-KX4-2" N1514.KX4.Dual.Description = "Intel(R) Ethernet X520 10GbE Dual Port KX4 Mezz" N10F8.KX4.KR.Dual.Description = "Intel(R) Ethernet X520 10GbE Dual Port KX4-KR Mezz" N10F8.KR.NDC.Description = "Intel(R) Ethernet 10G 2P X520-k bNDC" N1507.SFI.Dual.Description = "Intel(R) Ethernet ExpressModule X520-P2" N10F7.KX4.FEM.Description = "Sun Dual 10GbE PCIe 2.0 FEM" N1517.KR.Dual.Description = "Cisco UCS CNA M61KR-I Intel Converged Network Adapter" N154D.SFI.Dual.Description = "Intel(R) Ethernet 10G 2P X520 Adapter" HP10F8.KR.BLOM.Description = "HP Ethernet 10Gb 2-port 560FLB Adapter" HP10F8.KR.Dual.Description = "HP Ethernet 10Gb 2-port 560M Adapter" HP10FB.SFI.ALOM.Description = "HP Ethernet 10Gb 2-port 560FLR-SFP+ Adapter" HP10FB.SFI.ALOM.SP.Description = "HP Ethernet 10Gb 1-port P560FLR-SFP+ Adapter" HP10FB.SFI.LOM.Description = "HP Ethernet 10Gb 2-port 562i Adapter" N10FB.OCP.DP.Generic.Description = "Intel(R) Ethernet OCP Server Adapter X520-2" N1557.OCP.SP.Generic.Description = "Intel(R) Ethernet OCP Server Adapter X520-1" N10FB.SFI.FLEXLOM.Description = "Lenovo ThinkServer X520-2 AnyFabric" HP10FB.SFI.Dual.Description = "HP Ethernet 10Gb 2-port 560SFP+ Adapter" N10F9.Generic.Description = "Intel(R) 82599 10 Gigabit CX4 Dual Port Network Connection" N10FB.SFI.Single.Description = "Intel(R) Ethernet Server Adapter X520-1" N10FB.SFI.Dual.Description = "Intel(R) Ethernet Server Adapter X520-2" N10FB.CopperDA.Dual.Description = "Intel(R) Ethernet Server Adapter X520-DA2" N10FB.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Network Connection" N10FB.SFI.NDC.Description = "Intel(R) Ethernet 10G 4P X520/I350 rNDC" N10FB.SFI.ECNA.Description = "Intel(R) Ethernet 10GSFP+ DP Embedded CNA X520-2" N10FC.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Network Connection" N1529.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Network Connection with FCoE" N1557.Generic.Description = "Intel(R) 82599 10 Gigabit Network Connection" N151C.Copper.Dual.Description = "Intel(R) Ethernet Server Adapter X520-T2" N151C.Copper.Dual.Sun.Description = "Sun Dual 10GBASE-T LP" N151C.Generic.Description = "Intel(R) 82599 10 Gigabit TN Network Connection" N154A.SFI.Quad.Description = "Intel(R) Ethernet Converged Network Adapter X520-4" N1558.QSFP.Quad.Description = "Intel(R) Ethernet Converged Network Adapter X520-Q1" ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- [Strings.0C0A] ; Spanish (Spain) EnableLLI ="Interrupciones de baja latencia" LLIPorts ="Puertos de interrupciones de baja latencia" LLIPortBased ="Basado en puerto" LLIPSHBased ="Basado en indicador PSH" InterruptModeration ="Moderación de interrupciones" InterruptThrottleRate ="Velocidad de obstrucción de la interrupción" Adaptive ="Adaptación" Extreme ="Extremo" High ="Alto" Medium ="Medio" Low ="Bajo" IPChksumOffv4 ="Descarga de suma de comprobación de IPv4" TCPChksumOffv4 ="Descarga de suma de comprobación TCP (IPv4)" UDPChksumOffv4 ="Descarga de suma de comprobación UDP (IPv4)" LsoV2IPv4 ="Descarga grande de envío V2 (IPv4)" TCPChksumOffv6 ="Descarga de suma de comprobación TCP (IPv6)" UDPChksumOffv6 ="Descarga de suma de comprobación UDP (IPv6)" LsoV2IPv6 ="Descarga grande de envío V2 (IPv6)" ChksumOffTxRx ="Recepción y transmisión habilitadas" ChksumOffTx ="Transmisión habilitada" ChksumOffRx ="Recepción habilitada" TransmitBuffers ="Búferes de transmisión" ReceiveBuffers ="Búferes de recepción" RSS ="Receive Side Scaling" NumRssQueues2 ="Número máximo de colas de RSS" RSSProfile ="Perfil de distribución de carga de RSS" Closest_Processor ="Procesador más parecido" Closest_Processor_Static ="Procesador estático más parecido" NUMA_Scaling ="Escalado NUMA" NUMA_Scaling_Static ="Escalado estático NUMA" Conservative_Scaling ="Escalado conservador" RssBaseProcNumber ="CPU RSS inicial" MaxRssProcessors ="Número máximo de procesadores de RSS" NumaNodeId ="Nodo NUMA preferido" default ="Config. predeterminada del sistema" node0 ="Nodo 0" node1 ="Nodo 1" node2 ="Nodo 2" node3 ="Nodo 3" node4 ="Nodo 4" node5 ="Nodo 5" node6 ="Nodo 6" node7 ="Nodo 7" 1queue ="1 cola" 2queues ="2 colas" 4queues ="4 colas" 8queues ="8 colas" 16queues ="16 colas" IPsecOffloadV2 ="Descarga de IPsec" IPsecAH ="Encabezado de autenticación habilitado" IPsecESP ="ESP habilitado" IPSecAHESP ="Encabezado de autenticación y ESP habilitados" FCoEStartingNumaNodeId ="Nodo NUMA FCoE inicial" FCoENumaNodeCount ="Número de nodos NUMA FCoE" FCoEStartingRSSCoreNumber ="Número de núcleo RSS de FCoE inicial" FlowControl ="Control de flujo" FlowControl_RxOnly ="Recepción habilitada" FlowControl_TxOnly ="Transmisión habilitada" FlowControl_Full ="Recepción y transmisión habilitadas" PriorityVLANTag2 ="Prioridad de paquetes y VLAN " PriorityVlanDisabled2 ="Prioridad de paquetes y VLAN deshabilitadas" PriorityEnabled2 ="Prioridad de paquetes habilitada" PriorityVlanEnabled2 ="Prioridad de paquetes y VLAN habilitadas" VlanEnabled ="VLAN habilitada" SpeedDuplex ="Velocidad y dúplex" AutoNegotiation ="Negociación automática" 1000Mb_Full_Duplex ="Dúplex completo a 1,0 Gbps" 10Gb_Full_Duplex ="Dúplex completo a 10 Gbps" Off ="Desactivado" Enabled ="Habilitado" Disabled ="Deshabilitado" Bytes4088 ="4088 bytes" Bytes9014 ="9014 bytes" LAA ="Dirección administrada localmente" JumboPacket ="Paquete jumbo" RSCIPv4 ="Unión de segmentos de recepción (IPv4)" LogLinkState ="Registrar sucesos del estado del enlace" Enable_PME ="Activar PME" WakeOnMagicPacket ="Activar en Magic Packet" WakeOnPattern ="Activar al coincidir el patrón" VMQ ="Colas de máquina virtual" SRIOV ="SR-IOV" QOS ="NDIS QOS" SmartSpeed ="Smart Speed" ServiceName = "ixgbn" Intel = "Intel" EventLogMessageDllPath = "%SystemRoot%\System32\netevent.dll;%SystemRoot%\System32\ixnmsg.dll" DiskName = "Intel(R) PRO/10GbE Driver Disk" Service.Displayname = "Intel(R) PRO/10GbE PCIe-N Network Connection Driver" ;----------------------------------------------------------------------------- ; Device Description Strings ;----------------------------------------------------------------------------- O10A6.DeviceDesc = "Intel(R) 82599 Multi-Function Network Device" N10F7.Generic.Description = "Intel(R) 10 Gigabit BR KX4 Dual Port Network Connection" N10F8.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Backplane Connection" N152A.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Backplane Connection with FCoE" N10F7.KX4.Dual.Description = "Intel(R) Ethernet Mezzanine Adapter X520-KX4-2" N1514.KX4.Dual.Description = "Intel(R) Ethernet X520 10GbE Dual Port KX4 Mezz" N10F8.KX4.KR.Dual.Description = "Intel(R) Ethernet X520 10GbE Dual Port KX4-KR Mezz" N10F8.KR.NDC.Description = "Intel(R) Ethernet 10G 2P X520-k bNDC" N1507.SFI.Dual.Description = "Intel(R) Ethernet ExpressModule X520-P2" N10F7.KX4.FEM.Description = "Sun Dual 10GbE PCIe 2.0 FEM" N1517.KR.Dual.Description = "Cisco UCS CNA M61KR-I Intel Converged Network Adapter" N154D.SFI.Dual.Description = "Intel(R) Ethernet 10G 2P X520 Adapter" HP10F8.KR.BLOM.Description = "HP Ethernet 10Gb 2-port 560FLB Adapter" HP10F8.KR.Dual.Description = "HP Ethernet 10Gb 2-port 560M Adapter" HP10FB.SFI.ALOM.Description = "HP Ethernet 10Gb 2-port 560FLR-SFP+ Adapter" HP10FB.SFI.ALOM.SP.Description = "HP Ethernet 10Gb 1-port P560FLR-SFP+ Adapter" HP10FB.SFI.LOM.Description = "HP Ethernet 10Gb 2-port 562i Adapter" N10FB.OCP.DP.Generic.Description = "Intel(R) Ethernet OCP Server Adapter X520-2" N1557.OCP.SP.Generic.Description = "Intel(R) Ethernet OCP Server Adapter X520-1" N10FB.SFI.FLEXLOM.Description = "Lenovo ThinkServer X520-2 AnyFabric" HP10FB.SFI.Dual.Description = "HP Ethernet 10Gb 2-port 560SFP+ Adapter" N10F9.Generic.Description = "Intel(R) 82599 10 Gigabit CX4 Dual Port Network Connection" N10FB.SFI.Single.Description = "Intel(R) Ethernet Server Adapter X520-1" N10FB.SFI.Dual.Description = "Intel(R) Ethernet Server Adapter X520-2" N10FB.CopperDA.Dual.Description = "Intel(R) Ethernet Server Adapter X520-DA2" N10FB.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Network Connection" N10FB.SFI.NDC.Description = "Intel(R) Ethernet 10G 4P X520/I350 rNDC" N10FB.SFI.ECNA.Description = "Intel(R) Ethernet 10GSFP+ DP Embedded CNA X520-2" N10FC.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Network Connection" N1529.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Network Connection with FCoE" N1557.Generic.Description = "Intel(R) 82599 10 Gigabit Network Connection" N151C.Copper.Dual.Description = "Intel(R) Ethernet Server Adapter X520-T2" N151C.Copper.Dual.Sun.Description = "Sun Dual 10GBASE-T LP" N151C.Generic.Description = "Intel(R) 82599 10 Gigabit TN Network Connection" N154A.SFI.Quad.Description = "Intel(R) Ethernet Converged Network Adapter X520-4" N1558.QSFP.Quad.Description = "Intel(R) Ethernet Converged Network Adapter X520-Q1" ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- [Strings.040C] ; French (France) EnableLLI ="Interruptions à faible latence" LLIPorts ="Ports d'interruption à faible latence" LLIPortBased ="Basé sur le port" LLIPSHBased ="Basé sur le drapeau PSH" InterruptModeration ="Gestion des interruptions" InterruptThrottleRate ="Taux de gestion des interruptions" Adaptive ="Variable" Extreme ="Extrême" High ="Haut" Medium ="Moyen" Low ="Faible" IPChksumOffv4 ="Délester somme de contrôle IPv4" TCPChksumOffv4 ="Délester somme de contrôle TCP (IPv4)" UDPChksumOffv4 ="Délester somme de contrôle UDP (IPv4)" LsoV2IPv4 ="Délester envoi important v2 (IPv4)" TCPChksumOffv6 ="Délester somme de contrôle TCP (IPv6)" UDPChksumOffv6 ="Délester somme de contrôle UDP (IPv6)" LsoV2IPv6 ="Délester envoi important v2 (IPv6)" ChksumOffTxRx ="Rx et Tx activées" ChksumOffTx ="Tx activée" ChksumOffRx ="Rx activée" TransmitBuffers ="Tampons d'émission" ReceiveBuffers ="Tampons de réception" RSS ="Receive Side Scaling" NumRssQueues2 ="Nombre maximum de files d'attente RSS" RSSProfile ="Profil d'équilibrage de la charge RSS" Closest_Processor ="Processeur le plus proche" Closest_Processor_Static ="Processeur statique le plus proche" NUMA_Scaling ="Scaling NUMA" NUMA_Scaling_Static ="Scaling statique NUMA" Conservative_Scaling ="Scaling conservatif" RssBaseProcNumber ="Démarrage de la fonctionnalité RSS des processeurs" MaxRssProcessors ="Nombre maximum de processeurs RSS" NumaNodeId ="Nœud NUMA préféré" default ="Valeurs système par défaut" node0 ="Nœud 0" node1 ="Nœud 1" node2 ="Nœud 2" node3 ="Nœud 3" node4 ="Nœud 4" node5 ="Nœud 5" node6 ="Nœud 6" node7 ="Nœud 7" 1queue ="1 file d'attente" 2queues ="2 files d'attente" 4queues ="4 files d'attente" 8queues ="8 files d'attente" 16queues ="16 files d'attente" IPsecOffloadV2 ="Délestage sécurité IP" IPsecAH ="En-tête auth. activé" IPsecESP ="ESP activé" IPSecAHESP ="En-tête auth. et ESP activés" FCoEStartingNumaNodeId ="Nœud NUMA de départ FCoE" FCoENumaNodeCount ="Nombre de nœuds NUMA FCoE" FCoEStartingRSSCoreNumber ="Numéro de cœur RSS de départ FCoE" FlowControl ="Contrôle de flux" FlowControl_RxOnly ="Rx activée" FlowControl_TxOnly ="Tx activée" FlowControl_Full ="Rx et Tx activées" PriorityVLANTag2 ="Priorité des paquets et VLAN" PriorityVlanDisabled2 ="Priorité des paquets et VLAN désactivés" PriorityEnabled2 ="Priorité des paquets activée" PriorityVlanEnabled2 ="Priorité des paquets et VLAN activés" VlanEnabled ="VLAN activé" SpeedDuplex ="Vitesse et duplex" AutoNegotiation ="Négociation automatique" 1000Mb_Full_Duplex ="1,0 Gbits/s Duplex intégral" 10Gb_Full_Duplex ="10 Gbits/s Duplex intégral" Off ="Désactivé(e)" Enabled ="Activé(e)" Disabled ="Désactivé(e)" Bytes4088 ="4088 octets" Bytes9014 ="9014 octets" LAA ="Adresse administrée localement" JumboPacket ="Paquet étendu" RSCIPv4 ="Coalition matérielle des segments entrants (IPv4)" LogLinkState ="Consigner l'événement de la liaison" Enable_PME ="Activer PME" WakeOnMagicPacket ="Wake on Magic Packet" WakeOnPattern ="Wake on Pattern Match" VMQ ="Files d'attente d'ordinateurs virtuels" SRIOV ="SR-IOV" QOS ="NDIS QOS" SmartSpeed ="Smart Speed" ServiceName = "ixgbn" Intel = "Intel" EventLogMessageDllPath = "%SystemRoot%\System32\netevent.dll;%SystemRoot%\System32\ixnmsg.dll" DiskName = "Intel(R) PRO/10GbE Driver Disk" Service.Displayname = "Intel(R) PRO/10GbE PCIe-N Network Connection Driver" ;----------------------------------------------------------------------------- ; Device Description Strings ;----------------------------------------------------------------------------- O10A6.DeviceDesc = "Intel(R) 82599 Multi-Function Network Device" N10F7.Generic.Description = "Intel(R) 10 Gigabit BR KX4 Dual Port Network Connection" N10F8.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Backplane Connection" N152A.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Backplane Connection with FCoE" N10F7.KX4.Dual.Description = "Intel(R) Ethernet Mezzanine Adapter X520-KX4-2" N1514.KX4.Dual.Description = "Intel(R) Ethernet X520 10GbE Dual Port KX4 Mezz" N10F8.KX4.KR.Dual.Description = "Intel(R) Ethernet X520 10GbE Dual Port KX4-KR Mezz" N10F8.KR.NDC.Description = "Intel(R) Ethernet 10G 2P X520-k bNDC" N1507.SFI.Dual.Description = "Intel(R) Ethernet ExpressModule X520-P2" N10F7.KX4.FEM.Description = "Sun Dual 10GbE PCIe 2.0 FEM" N1517.KR.Dual.Description = "Cisco UCS CNA M61KR-I Intel Converged Network Adapter" N154D.SFI.Dual.Description = "Intel(R) Ethernet 10G 2P X520 Adapter" HP10F8.KR.BLOM.Description = "HP Ethernet 10Gb 2-port 560FLB Adapter" HP10F8.KR.Dual.Description = "HP Ethernet 10Gb 2-port 560M Adapter" HP10FB.SFI.ALOM.Description = "HP Ethernet 10Gb 2-port 560FLR-SFP+ Adapter" HP10FB.SFI.ALOM.SP.Description = "HP Ethernet 10Gb 1-port P560FLR-SFP+ Adapter" HP10FB.SFI.LOM.Description = "HP Ethernet 10Gb 2-port 562i Adapter" N10FB.OCP.DP.Generic.Description = "Intel(R) Ethernet OCP Server Adapter X520-2" N1557.OCP.SP.Generic.Description = "Intel(R) Ethernet OCP Server Adapter X520-1" N10FB.SFI.FLEXLOM.Description = "Lenovo ThinkServer X520-2 AnyFabric" HP10FB.SFI.Dual.Description = "HP Ethernet 10Gb 2-port 560SFP+ Adapter" N10F9.Generic.Description = "Intel(R) 82599 10 Gigabit CX4 Dual Port Network Connection" N10FB.SFI.Single.Description = "Intel(R) Ethernet Server Adapter X520-1" N10FB.SFI.Dual.Description = "Intel(R) Ethernet Server Adapter X520-2" N10FB.CopperDA.Dual.Description = "Intel(R) Ethernet Server Adapter X520-DA2" N10FB.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Network Connection" N10FB.SFI.NDC.Description = "Intel(R) Ethernet 10G 4P X520/I350 rNDC" N10FB.SFI.ECNA.Description = "Intel(R) Ethernet 10GSFP+ DP Embedded CNA X520-2" N10FC.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Network Connection" N1529.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Network Connection with FCoE" N1557.Generic.Description = "Intel(R) 82599 10 Gigabit Network Connection" N151C.Copper.Dual.Description = "Intel(R) Ethernet Server Adapter X520-T2" N151C.Copper.Dual.Sun.Description = "Sun Dual 10GBASE-T LP" N151C.Generic.Description = "Intel(R) 82599 10 Gigabit TN Network Connection" N154A.SFI.Quad.Description = "Intel(R) Ethernet Converged Network Adapter X520-4" N1558.QSFP.Quad.Description = "Intel(R) Ethernet Converged Network Adapter X520-Q1" ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- [Strings.0410] ; Italian (Italy) EnableLLI ="Interrupt a bassa latenza" LLIPorts ="Porte di interrupt a bassa latenza" LLIPortBased ="Basato su porta" LLIPSHBased ="Basato su flag PSH" InterruptModeration ="Interrompi moderazione" InterruptThrottleRate ="Velocità di rallentamento dell'interrupt" Adaptive ="Adattivo" Extreme ="Estremo" High ="Alto" Medium ="Medio" Low ="Basso" IPChksumOffv4 ="Offload di checksum IPv4" TCPChksumOffv4 ="Offload di checksum TCP (IPv4)" UDPChksumOffv4 ="Offload di checksum UDP (IPv4)" LsoV2IPv4 ="Large Send Offload V2 (IPv4)" TCPChksumOffv6 ="Offload di checksum TCP (IPv6)" UDPChksumOffv6 ="Offload di checksum UDP (IPv6)" LsoV2IPv6 ="Large Send Offload V2 (IPv6)" ChksumOffTxRx ="Rx e Tx abilitate" ChksumOffTx ="Tx abilitata" ChksumOffRx ="Rx abilitata" TransmitBuffers ="Trasmetti buffer" ReceiveBuffers ="Ricevi buffer" RSS ="Receive Side Scaling" NumRssQueues2 ="Numero massimo di code RSS" RSSProfile ="Profilo di bilanciamento del carico RSS" Closest_Processor ="Processore più simile" Closest_Processor_Static ="Processore statico più simile" NUMA_Scaling ="Scaling NUMA" NUMA_Scaling_Static ="Scaling statico NUMA" Conservative_Scaling ="Scaling conservativo" RssBaseProcNumber ="Avvio di CPU RSS" MaxRssProcessors ="Numero massimo di processori RSS" NumaNodeId ="Nodo NUMA preferito" default ="Impostazioni predefinite sistema" node0 ="Nodo 0" node1 ="Nodo 1" node2 ="Nodo 2" node3 ="Nodo 3" node4 ="Nodo 4" node5 ="Nodo 5" node6 ="Nodo 6" node7 ="Nodo 7" 1queue ="1 coda" 2queues ="2 code" 4queues ="4 code" 8queues ="8 code" 16queues ="16 code" IPsecOffloadV2 ="Offload IPsec" IPsecAH ="Intestazione di autenticazione abilitata" IPsecESP ="ESP abilitato" IPSecAHESP ="Intestazione di autenticazione ed ESP abilitati" FCoEStartingNumaNodeId ="Nodo NUMA iniziale FCoE" FCoENumaNodeCount ="Numero di nodi NUMA FCoE" FCoEStartingRSSCoreNumber ="Numero di core RSS iniziali FCoE" FlowControl ="Controllo del flusso" FlowControl_RxOnly ="Rx abilitata" FlowControl_TxOnly ="Tx abilitata" FlowControl_Full ="Rx e Tx abilitate" PriorityVLANTag2 ="Priorità pacchetti e VLAN" PriorityVlanDisabled2 ="Priorità pacchetti e VLAN disattivate" PriorityEnabled2 ="Priorità pacchetti attivata" PriorityVlanEnabled2 ="Priorità pacchetti e VLAN attivate" VlanEnabled ="VLAN abilitata" SpeedDuplex ="Velocità e duplex" AutoNegotiation ="Negoziazione automatica" 1000Mb_Full_Duplex ="1.0 Gbps Full Duplex" 10Gb_Full_Duplex ="10 Gbps Full Duplex" Off ="Disattivato" Enabled ="Attivato" Disabled ="Disattivato" Bytes4088 ="4088 byte" Bytes9014 ="9014 byte" LAA ="Indirizzo amministrato localmente" JumboPacket ="Pacchetto Jumbo" RSCIPv4 ="Unione dei segmenti di ricezione (IPv4)" LogLinkState ="Registra evento stato del collegamento" Enable_PME ="Abilita PME" WakeOnMagicPacket ="Attiva su pacchetto Magic" WakeOnPattern ="Attiva su Pattern Match" VMQ ="Code macchine virtuali" SRIOV ="SR-IOV" QOS ="NDIS QOS" SmartSpeed ="Smart Speed" ServiceName = "ixgbn" Intel = "Intel" EventLogMessageDllPath = "%SystemRoot%\System32\netevent.dll;%SystemRoot%\System32\ixnmsg.dll" DiskName = "Intel(R) PRO/10GbE Driver Disk" Service.Displayname = "Intel(R) PRO/10GbE PCIe-N Network Connection Driver" ;----------------------------------------------------------------------------- ; Device Description Strings ;----------------------------------------------------------------------------- O10A6.DeviceDesc = "Intel(R) 82599 Multi-Function Network Device" N10F7.Generic.Description = "Intel(R) 10 Gigabit BR KX4 Dual Port Network Connection" N10F8.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Backplane Connection" N152A.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Backplane Connection with FCoE" N10F7.KX4.Dual.Description = "Intel(R) Ethernet Mezzanine Adapter X520-KX4-2" N1514.KX4.Dual.Description = "Intel(R) Ethernet X520 10GbE Dual Port KX4 Mezz" N10F8.KX4.KR.Dual.Description = "Intel(R) Ethernet X520 10GbE Dual Port KX4-KR Mezz" N10F8.KR.NDC.Description = "Intel(R) Ethernet 10G 2P X520-k bNDC" N1507.SFI.Dual.Description = "Intel(R) Ethernet ExpressModule X520-P2" N10F7.KX4.FEM.Description = "Sun Dual 10GbE PCIe 2.0 FEM" N1517.KR.Dual.Description = "Cisco UCS CNA M61KR-I Intel Converged Network Adapter" N154D.SFI.Dual.Description = "Intel(R) Ethernet 10G 2P X520 Adapter" HP10F8.KR.BLOM.Description = "HP Ethernet 10Gb 2-port 560FLB Adapter" HP10F8.KR.Dual.Description = "HP Ethernet 10Gb 2-port 560M Adapter" HP10FB.SFI.ALOM.Description = "HP Ethernet 10Gb 2-port 560FLR-SFP+ Adapter" HP10FB.SFI.ALOM.SP.Description = "HP Ethernet 10Gb 1-port P560FLR-SFP+ Adapter" HP10FB.SFI.LOM.Description = "HP Ethernet 10Gb 2-port 562i Adapter" N10FB.OCP.DP.Generic.Description = "Intel(R) Ethernet OCP Server Adapter X520-2" N1557.OCP.SP.Generic.Description = "Intel(R) Ethernet OCP Server Adapter X520-1" N10FB.SFI.FLEXLOM.Description = "Lenovo ThinkServer X520-2 AnyFabric" HP10FB.SFI.Dual.Description = "HP Ethernet 10Gb 2-port 560SFP+ Adapter" N10F9.Generic.Description = "Intel(R) 82599 10 Gigabit CX4 Dual Port Network Connection" N10FB.SFI.Single.Description = "Intel(R) Ethernet Server Adapter X520-1" N10FB.SFI.Dual.Description = "Intel(R) Ethernet Server Adapter X520-2" N10FB.CopperDA.Dual.Description = "Intel(R) Ethernet Server Adapter X520-DA2" N10FB.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Network Connection" N10FB.SFI.NDC.Description = "Intel(R) Ethernet 10G 4P X520/I350 rNDC" N10FB.SFI.ECNA.Description = "Intel(R) Ethernet 10GSFP+ DP Embedded CNA X520-2" N10FC.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Network Connection" N1529.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Network Connection with FCoE" N1557.Generic.Description = "Intel(R) 82599 10 Gigabit Network Connection" N151C.Copper.Dual.Description = "Intel(R) Ethernet Server Adapter X520-T2" N151C.Copper.Dual.Sun.Description = "Sun Dual 10GBASE-T LP" N151C.Generic.Description = "Intel(R) 82599 10 Gigabit TN Network Connection" N154A.SFI.Quad.Description = "Intel(R) Ethernet Converged Network Adapter X520-4" N1558.QSFP.Quad.Description = "Intel(R) Ethernet Converged Network Adapter X520-Q1" ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- [Strings.0411] ; Japanese (Japan) EnableLLI ="’჌ƒCƒeƒ“ƒV[Š„‚èž‚Ý" LLIPorts ="’჌ƒCƒeƒ“ƒV[Š„‚螂݃|[ƒg" LLIPortBased ="ƒ|[ƒg ƒx[ƒX" LLIPSHBased ="PSH ƒtƒ‰ƒO ƒx[ƒX" InterruptModeration ="Š„‚螂݉ÁŒ¸" InterruptThrottleRate ="Š„‚螂݉ÁŒ¸—¦" Adaptive ="ƒAƒ_ƒvƒeƒBƒu" Extreme ="Å‘å" High ="‚" Medium ="’†" Low ="’á" IPChksumOffv4 ="IPv4 ƒ`ƒFƒbƒNƒTƒ€‚̃Iƒtƒ[ƒh" TCPChksumOffv4 ="TCP ƒ`ƒFƒbƒNƒTƒ€‚̃Iƒtƒ[ƒh (IPv4)" UDPChksumOffv4 ="UDP ƒ`ƒFƒbƒNƒTƒ€‚̃Iƒtƒ[ƒh (IPv4)" LsoV2IPv4 ="‘å—Ê‘—MƒIƒtƒ[ƒh V2 (IPv4)" TCPChksumOffv6 ="TCP ƒ`ƒFƒbƒNƒTƒ€‚̃Iƒtƒ[ƒh (IPv6)" UDPChksumOffv6 ="UDP ƒ`ƒFƒbƒNƒTƒ€‚̃Iƒtƒ[ƒh (IPv6)" LsoV2IPv6 ="‘å—Ê‘—MƒIƒtƒ[ƒh V2 (IPv6)" ChksumOffTxRx ="ŽóM/‘—M —LŒø" ChksumOffTx ="‘—M —LŒø" ChksumOffRx ="ŽóM —LŒø" TransmitBuffers ="‘—Mƒoƒbƒtƒ@" ReceiveBuffers ="ŽóMƒoƒbƒtƒ@" RSS ="ŽóM‘¤ƒXƒP[ƒŠƒ“ƒO" NumRssQueues2 ="RSS ƒLƒ…[‚ÌÅ‘å”" RSSProfile ="RSS ƒ[ƒhEƒoƒ‰ƒ“ƒVƒ“ƒOEƒvƒƒtƒ@ƒCƒ‹" Closest_Processor ="Å‚à‹ß‚¢ƒvƒƒZƒbƒT[" Closest_Processor_Static ="Å‚à‹ß‚¢ƒvƒƒZƒbƒT[EƒXƒ^ƒeƒBƒbƒN" NUMA_Scaling ="NUMA ƒXƒP[ƒŠƒ“ƒO" NUMA_Scaling_Static ="NUMA ƒXƒP[ƒŠƒ“ƒOEƒXƒ^ƒeƒBƒbƒN" Conservative_Scaling ="ƒRƒ“ƒT[ƒoƒeƒBƒuEƒXƒP[ƒŠƒ“ƒO" RssBaseProcNumber ="RSS CPU ‚ÌŠJŽn" MaxRssProcessors ="RSS ƒvƒƒZƒbƒT[‚ÌÅ‘å”" NumaNodeId ="—Dæ NUMA ƒm[ƒh" default ="ƒVƒXƒeƒ€ƒfƒtƒHƒ‹ƒg" node0 ="ƒm[ƒh 0" node1 ="ƒm[ƒh 1" node2 ="ƒm[ƒh 2" node3 ="ƒm[ƒh 3" node4 ="ƒm[ƒh 4" node5 ="ƒm[ƒh 5" node6 ="ƒm[ƒh 6" node7 ="ƒm[ƒh 7" 1queue ="1 ƒLƒ…[" 2queues ="2 ƒLƒ…[" 4queues ="4 ƒLƒ…[" 8queues ="8 ƒLƒ…[" 16queues ="16 ƒLƒ…[" IPsecOffloadV2 ="IPSec ƒIƒtƒ[ƒh" IPsecAH ="”F؃wƒbƒ_[—LŒø" IPsecESP ="ESP —LŒø" IPSecAHESP ="”F؃wƒbƒ_[‚Æ ESP —LŒø" FCoEStartingNumaNodeId ="FCoE ŠJŽn NUMA ƒm[ƒh" FCoENumaNodeCount ="FCoE NUMA ƒm[ƒhƒJƒEƒ“ƒg" FCoEStartingRSSCoreNumber ="FCoE ŠJŽn RSS ƒRƒA”Ô†" FlowControl ="ƒtƒ[§Œä" FlowControl_RxOnly ="ŽóM —LŒø" FlowControl_TxOnly ="‘—M —LŒø" FlowControl_Full ="ŽóM/‘—M —LŒø" PriorityVLANTag2 ="—DæƒpƒPƒbƒg‚Æ VLAN" PriorityVlanDisabled2 ="—DæƒpƒPƒbƒg‚Æ VLAN –³Œø" PriorityEnabled2 ="—DæƒpƒPƒbƒg—LŒø" PriorityVlanEnabled2 ="—DæƒpƒPƒbƒg‚Æ VLAN —LŒø" VlanEnabled ="VLAN —LŒø" SpeedDuplex ="‘¬“x‚ƃfƒ…ƒvƒŒƒbƒNƒX" AutoNegotiation ="ƒI[ƒgƒlƒSƒVƒG[ƒVƒ‡ƒ“" 1000Mb_Full_Duplex ="1.0 Gbps ‘S“ñd’ÊM" 10Gb_Full_Duplex ="10 Gbps ‘S“ñd’ÊM" Off ="ƒIƒt" Enabled ="ƒIƒ“" Disabled ="ƒIƒt" Bytes4088 ="4088 ƒoƒCƒg" Bytes9014 ="9014 ƒoƒCƒg" LAA ="ƒ[ƒJƒ‹ŠÇ—‚³‚ê‚éƒAƒhƒŒƒX" JumboPacket ="ƒWƒƒƒ“ƒ{ ƒpƒPƒbƒg" RSCIPv4 ="ŽóM‘¤ƒZƒOƒƒ“ƒgEƒRƒAƒŒƒVƒ“ƒO (IPv4)" LogLinkState ="ƒŠƒ“ƒN ƒXƒe[ƒg ƒCƒxƒ“ƒg‚̃ƒO" Enable_PME ="PME ‚ðƒIƒ“‚É‚·‚é" WakeOnMagicPacket ="Wake On Magic Packet" WakeOnPattern ="Wake on Pattern Match" VMQ ="‰¼‘zƒ}ƒVƒ“ƒLƒ…[" SRIOV ="SR-IOV" QOS ="NDIS QOS" SmartSpeed ="ƒXƒ}[ƒgƒXƒs[ƒh" ServiceName = "ixgbn" Intel = "Intel" EventLogMessageDllPath = "%SystemRoot%\System32\netevent.dll;%SystemRoot%\System32\ixnmsg.dll" DiskName = "Intel(R) PRO/10GbE Driver Disk" Service.Displayname = "Intel(R) PRO/10GbE PCIe-N Network Connection Driver" ;----------------------------------------------------------------------------- ; Device Description Strings ;----------------------------------------------------------------------------- O10A6.DeviceDesc = "Intel(R) 82599 Multi-Function Network Device" N10F7.Generic.Description = "Intel(R) 10 Gigabit BR KX4 Dual Port Network Connection" N10F8.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Backplane Connection" N152A.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Backplane Connection with FCoE" N10F7.KX4.Dual.Description = "Intel(R) Ethernet Mezzanine Adapter X520-KX4-2" N1514.KX4.Dual.Description = "Intel(R) Ethernet X520 10GbE Dual Port KX4 Mezz" N10F8.KX4.KR.Dual.Description = "Intel(R) Ethernet X520 10GbE Dual Port KX4-KR Mezz" N10F8.KR.NDC.Description = "Intel(R) Ethernet 10G 2P X520-k bNDC" N1507.SFI.Dual.Description = "Intel(R) Ethernet ExpressModule X520-P2" N10F7.KX4.FEM.Description = "Sun Dual 10GbE PCIe 2.0 FEM" N1517.KR.Dual.Description = "Cisco UCS CNA M61KR-I Intel Converged Network Adapter" N154D.SFI.Dual.Description = "Intel(R) Ethernet 10G 2P X520 Adapter" HP10F8.KR.BLOM.Description = "HP Ethernet 10Gb 2-port 560FLB Adapter" HP10F8.KR.Dual.Description = "HP Ethernet 10Gb 2-port 560M Adapter" HP10FB.SFI.ALOM.Description = "HP Ethernet 10Gb 2-port 560FLR-SFP+ Adapter" HP10FB.SFI.ALOM.SP.Description = "HP Ethernet 10Gb 1-port P560FLR-SFP+ Adapter" HP10FB.SFI.LOM.Description = "HP Ethernet 10Gb 2-port 562i Adapter" N10FB.OCP.DP.Generic.Description = "Intel(R) Ethernet OCP Server Adapter X520-2" N1557.OCP.SP.Generic.Description = "Intel(R) Ethernet OCP Server Adapter X520-1" N10FB.SFI.FLEXLOM.Description = "Lenovo ThinkServer X520-2 AnyFabric" HP10FB.SFI.Dual.Description = "HP Ethernet 10Gb 2-port 560SFP+ Adapter" N10F9.Generic.Description = "Intel(R) 82599 10 Gigabit CX4 Dual Port Network Connection" N10FB.SFI.Single.Description = "Intel(R) Ethernet Server Adapter X520-1" N10FB.SFI.Dual.Description = "Intel(R) Ethernet Server Adapter X520-2" N10FB.CopperDA.Dual.Description = "Intel(R) Ethernet Server Adapter X520-DA2" N10FB.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Network Connection" N10FB.SFI.NDC.Description = "Intel(R) Ethernet 10G 4P X520/I350 rNDC" N10FB.SFI.ECNA.Description = "Intel(R) Ethernet 10GSFP+ DP Embedded CNA X520-2" N10FC.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Network Connection" N1529.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Network Connection with FCoE" N1557.Generic.Description = "Intel(R) 82599 10 Gigabit Network Connection" N151C.Copper.Dual.Description = "Intel(R) Ethernet Server Adapter X520-T2" N151C.Copper.Dual.Sun.Description = "Sun Dual 10GBASE-T LP" N151C.Generic.Description = "Intel(R) 82599 10 Gigabit TN Network Connection" N154A.SFI.Quad.Description = "Intel(R) Ethernet Converged Network Adapter X520-4" N1558.QSFP.Quad.Description = "Intel(R) Ethernet Converged Network Adapter X520-Q1" ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- [Strings.0412] ; Korean (Korea) EnableLLI ="³·Àº ´ë±â ½Ã°£ ÀÎÅÍ·´Æ®" LLIPorts ="³·Àº ´ë±â ½Ã°£ ÀÎÅÍ·´Æ® Æ÷Æ®" LLIPortBased ="Æ÷Æ® ±â¹Ý" LLIPSHBased ="PSH Ç÷¡±× ±â¹Ý" InterruptModeration ="ÀÎÅÍ·´Æ® Á¶Àý" InterruptThrottleRate ="ÀÎÅÍ·´Æ® Á¶Àý ¼Óµµ" Adaptive ="ÀûÀÀ" Extreme ="ÃÖ´ë" High ="³ôÀ½" Medium ="Áß°£" Low ="³·À½" IPChksumOffv4 ="IPv4 üũ¼¶ ¿ÀÇÁ·Îµå" TCPChksumOffv4 ="TCP üũ¼¶ ¿ÀÇÁ·Îµå(IPv4)" UDPChksumOffv4 ="UDP üũ¼¶ ¿ÀÇÁ·Îµå(IPv4)" LsoV2IPv4 ="´ëÇü Àü¼Û ¿ÀÇÁ·Îµå V2(IPv4)" TCPChksumOffv6 ="TCP üũ¼¶ ¿ÀÇÁ·Îµå(IPv6)" UDPChksumOffv6 ="UDP üũ¼¶ ¿ÀÇÁ·Îµå(IPv6)" LsoV2IPv6 ="´ëÇü Àü¼Û ¿ÀÇÁ·Îµå V2(IPv6)" ChksumOffTxRx ="Rx & Tx È°¼ºÈ­µÊ" ChksumOffTx ="Tx È°¼ºÈ­µÊ" ChksumOffRx ="Rx È°¼ºÈ­µÊ" TransmitBuffers ="Àü¼Û ¹öÆÛ" ReceiveBuffers ="¼ö½Å ¹öÆÛ" RSS ="¼ö½ÅÃø ¹èÀ²" NumRssQueues2 ="ÃÖ´ë RSS ´ë±â¿­ ¼ö" RSSProfile ="RSS ·Îµå ¹ë·±½Ì ÇÁ·ÎÆÄÀÏ" Closest_Processor ="°¡Àå °¡±î¿î ÇÁ·Î¼¼¼­" Closest_Processor_Static ="°¡Àå °¡±î¿î ÇÁ·Î¼¼¼­(Á¤Àû)" NUMA_Scaling ="NUMA Á¶Á¤" NUMA_Scaling_Static ="NUMA Á¶Á¤(Á¤Àû)" Conservative_Scaling ="º¸¼öÀû Á¶Á¤" RssBaseProcNumber ="RSS CPU ½ÃÀÛ" MaxRssProcessors ="ÃÖ´ë RSS ÇÁ·Î¼¼¼­ ¼ö" NumaNodeId ="±âº» ¼³Á¤ NUMA ³ëµå" default ="½Ã½ºÅÛ ±âº»°ª" node0 ="³ëµå 0" node1 ="³ëµå 1" node2 ="³ëµå 2" node3 ="³ëµå 3" node4 ="³ëµå 4" node5 ="³ëµå 5" node6 ="³ëµå 6" node7 ="³ëµå 7" 1queue ="1°³ÀÇ ´ë±â¿­" 2queues ="2°³ÀÇ ´ë±â¿­" 4queues ="4°³ÀÇ ´ë±â¿­" 8queues ="8°³ÀÇ ´ë±â¿­" 16queues ="16°³ÀÇ ´ë±â¿­" IPsecOffloadV2 ="IPsec ¿ÀÇÁ·Îµå" IPsecAH ="Auth Çì´õ È°¼ºÈ­µÊ" IPsecESP ="ESP È°¼ºÈ­µÊ" IPSecAHESP ="Auth Çì´õ ¹× ESP È°¼ºÈ­µÊ" FCoEStartingNumaNodeId ="FCoE ½ÃÀÛ NUMA ³ëµå" FCoENumaNodeCount ="FCoE NUMA ³ëµå Ä«¿îÆ®" FCoEStartingRSSCoreNumber ="FCoE ½ÃÀÛ RSS ÄÚ¾î ¹øÈ£" FlowControl ="È帧 Á¦¾î" FlowControl_RxOnly ="Rx È°¼ºÈ­µÊ" FlowControl_TxOnly ="Tx È°¼ºÈ­µÊ" FlowControl_Full ="Rx & Tx È°¼ºÈ­µÊ" PriorityVLANTag2 ="ÆÐŶ ¿ì¼±¼øÀ§ ¹× VLAN" PriorityVlanDisabled2 ="ÆÐŶ ¿ì¼±¼øÀ§ ¹× VLAN ºñÈ°¼ºÈ­µÊ" PriorityEnabled2 ="ÆÐŶ ¿ì¼±¼øÀ§ È°¼ºÈ­µÊ" PriorityVlanEnabled2 ="ÆÐŶ ¿ì¼±¼øÀ§ ¹× VLAN È°¼ºÈ­µÊ" VlanEnabled ="VLAN È°¼ºÈ­µÊ" SpeedDuplex ="¼Óµµ ¹× ÀÌÁß¼º" AutoNegotiation ="ÀÚµ¿ Çù»ó" 1000Mb_Full_Duplex ="1.0 Gbps ÀüÀÌÁß" 10Gb_Full_Duplex ="10 Gbps ÀüÀÌÁß" Off ="¿ÀÇÁ" Enabled ="È°¼ºÈ­µÊ" Disabled ="ºñÈ°¼ºÈ­µÊ" Bytes4088 ="4088¹ÙÀÌÆ®" Bytes9014 ="9014¹ÙÀÌÆ®" LAA ="·ÎÄà °ü¸® ÁÖ¼Ò" JumboPacket ="Á¡º¸ ÆÐŶ" RSCIPv4 ="¼ö½Å ¼¼±×¸ÕÆ® ÅëÇÕ(IPv4)" LogLinkState ="¸µÅ© »óÅ À̺¥Æ® ±â·Ï" Enable_PME ="PME È°¼ºÈ­" WakeOnMagicPacket ="Wake on Magic Packet" WakeOnPattern ="Wake on Pattern Match" VMQ ="°¡»ó ½Ã½ºÅÛ ´ë±â¿­" SRIOV ="SR-IOV" QOS ="NDIS QOS" SmartSpeed ="½º¸¶Æ® ½ºÇǵå" ServiceName = "ixgbn" Intel = "Intel" EventLogMessageDllPath = "%SystemRoot%\System32\netevent.dll;%SystemRoot%\System32\ixnmsg.dll" DiskName = "Intel(R) PRO/10GbE Driver Disk" Service.Displayname = "Intel(R) PRO/10GbE PCIe-N Network Connection Driver" ;----------------------------------------------------------------------------- ; Device Description Strings ;----------------------------------------------------------------------------- O10A6.DeviceDesc = "Intel(R) 82599 Multi-Function Network Device" N10F7.Generic.Description = "Intel(R) 10 Gigabit BR KX4 Dual Port Network Connection" N10F8.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Backplane Connection" N152A.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Backplane Connection with FCoE" N10F7.KX4.Dual.Description = "Intel(R) Ethernet Mezzanine Adapter X520-KX4-2" N1514.KX4.Dual.Description = "Intel(R) Ethernet X520 10GbE Dual Port KX4 Mezz" N10F8.KX4.KR.Dual.Description = "Intel(R) Ethernet X520 10GbE Dual Port KX4-KR Mezz" N10F8.KR.NDC.Description = "Intel(R) Ethernet 10G 2P X520-k bNDC" N1507.SFI.Dual.Description = "Intel(R) Ethernet ExpressModule X520-P2" N10F7.KX4.FEM.Description = "Sun Dual 10GbE PCIe 2.0 FEM" N1517.KR.Dual.Description = "Cisco UCS CNA M61KR-I Intel Converged Network Adapter" N154D.SFI.Dual.Description = "Intel(R) Ethernet 10G 2P X520 Adapter" HP10F8.KR.BLOM.Description = "HP Ethernet 10Gb 2-port 560FLB Adapter" HP10F8.KR.Dual.Description = "HP Ethernet 10Gb 2-port 560M Adapter" HP10FB.SFI.ALOM.Description = "HP Ethernet 10Gb 2-port 560FLR-SFP+ Adapter" HP10FB.SFI.ALOM.SP.Description = "HP Ethernet 10Gb 1-port P560FLR-SFP+ Adapter" HP10FB.SFI.LOM.Description = "HP Ethernet 10Gb 2-port 562i Adapter" N10FB.OCP.DP.Generic.Description = "Intel(R) Ethernet OCP Server Adapter X520-2" N1557.OCP.SP.Generic.Description = "Intel(R) Ethernet OCP Server Adapter X520-1" N10FB.SFI.FLEXLOM.Description = "Lenovo ThinkServer X520-2 AnyFabric" HP10FB.SFI.Dual.Description = "HP Ethernet 10Gb 2-port 560SFP+ Adapter" N10F9.Generic.Description = "Intel(R) 82599 10 Gigabit CX4 Dual Port Network Connection" N10FB.SFI.Single.Description = "Intel(R) Ethernet Server Adapter X520-1" N10FB.SFI.Dual.Description = "Intel(R) Ethernet Server Adapter X520-2" N10FB.CopperDA.Dual.Description = "Intel(R) Ethernet Server Adapter X520-DA2" N10FB.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Network Connection" N10FB.SFI.NDC.Description = "Intel(R) Ethernet 10G 4P X520/I350 rNDC" N10FB.SFI.ECNA.Description = "Intel(R) Ethernet 10GSFP+ DP Embedded CNA X520-2" N10FC.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Network Connection" N1529.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Network Connection with FCoE" N1557.Generic.Description = "Intel(R) 82599 10 Gigabit Network Connection" N151C.Copper.Dual.Description = "Intel(R) Ethernet Server Adapter X520-T2" N151C.Copper.Dual.Sun.Description = "Sun Dual 10GBASE-T LP" N151C.Generic.Description = "Intel(R) 82599 10 Gigabit TN Network Connection" N154A.SFI.Quad.Description = "Intel(R) Ethernet Converged Network Adapter X520-4" N1558.QSFP.Quad.Description = "Intel(R) Ethernet Converged Network Adapter X520-Q1" ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- [Strings.0416] ; Portuguese (Brazil) EnableLLI ="Interrupções de baixa latência" LLIPorts ="Portas de interrupções de baixa latência" LLIPortBased ="Baseado em porta" LLIPSHBased ="Baseado no sinalizador PSH" InterruptModeration ="Moderação de interrupções" InterruptThrottleRate ="Taxa de moderação de interrupções" Adaptive ="Adaptativa" Extreme ="Extremo" High ="Alto" Medium ="Médio" Low ="Baixo" IPChksumOffv4 ="Offload Checksum IPv4" TCPChksumOffv4 ="Offload Checksum de TCP (IPv4)" UDPChksumOffv4 ="Offload Checksum UDP (IPv4)" LsoV2IPv4 ="Offload grande de envio v2 (IPv4)" TCPChksumOffv6 ="Offload Checksum de TCP (IPv6)" UDPChksumOffv6 ="Offload Checksum UDP (IPv6)" LsoV2IPv6 ="Offload grande de envio v2 (IPv6)" ChksumOffTxRx ="Rx e TX habilitadas" ChksumOffTx ="Tx habilitada" ChksumOffRx ="Rx habilitada" TransmitBuffers ="Buffers de transmissão" ReceiveBuffers ="Buffers de recepção" RSS ="Escala de recepção" NumRssQueues2 ="Nº máx. de filas de RSS" RSSProfile ="Perfil de equilíbrio de carga de RSS" Closest_Processor ="Processador mais próximo" Closest_Processor_Static ="Processador estático mais próximo" NUMA_Scaling ="Escala NUMA" NUMA_Scaling_Static ="Escala estática NUMA" Conservative_Scaling ="Escala conservadora" RssBaseProcNumber ="Iniciando a CPU de RSS" MaxRssProcessors ="Nº máx. de processadores de RSS" NumaNodeId ="Nó NUMA preferencial" default ="Padrão do sistema" node0 ="Nó 0" node1 ="Nó 1" node2 ="Nó 2" node3 ="Nó 3" node4 ="Nó 4" node5 ="Nó 5" node6 ="Nó 6" node7 ="Nó 7" 1queue ="1 fila" 2queues ="2 filas" 4queues ="4 filas" 8queues ="8 Filas" 16queues ="16 Filas" IPsecOffloadV2 ="Descarregamento do IPsec" IPsecAH ="Cabeçalho de autorização ativado" IPsecESP ="ESP habilitado" IPSecAHESP ="Cabeçalho de autorização e ESP habilitados" FCoEStartingNumaNodeId ="Nó NUMA inicial de FCoE" FCoENumaNodeCount ="Total de nós NUMA de FCoE" FCoEStartingRSSCoreNumber ="Número núcleo de RSS inicial de FCoE" FlowControl ="Controle de fluxo" FlowControl_RxOnly ="Rx habilitada" FlowControl_TxOnly ="Tx habilitada" FlowControl_Full ="Rx e TX habilitadas" PriorityVLANTag2 ="Prioridade de pacotes e VLAN" PriorityVlanDisabled2 ="Prioridade de pacotes e VLAN desabilitadas" PriorityEnabled2 ="Prioridade de pacotes habilitada" PriorityVlanEnabled2 ="Prioridade de pacotes e VLAN habilitadas" VlanEnabled ="VLAN habilitada" SpeedDuplex ="Velocidade e duplex" AutoNegotiation ="Negociação automática" 1000Mb_Full_Duplex ="Full-duplex de 1,0 Gbps" 10Gb_Full_Duplex ="Full-duplex de 10 Gbps" Off ="Desligado" Enabled ="Habilitada" Disabled ="Desabilitada" Bytes4088 ="4088 Bytes" Bytes9014 ="9014 Bytes" LAA ="Endereço administrado localmente (LAA)" JumboPacket ="Pacote grande" RSCIPv4 ="Coalescência de segmentos recebidos (IPv4)" LogLinkState ="Evento de estado de link de registro" Enable_PME ="Habilitar PME" WakeOnMagicPacket ="Ativar com Magic Packet" WakeOnPattern ="Despertar quando padrão coincide" VMQ ="Filas de máquina virtual" SRIOV ="SR-IOV" QOS ="QOS de NDIS" SmartSpeed ="Smart Speed" ServiceName = "ixgbn" Intel = "Intel" EventLogMessageDllPath = "%SystemRoot%\System32\netevent.dll;%SystemRoot%\System32\ixnmsg.dll" DiskName = "Intel(R) PRO/10GbE Driver Disk" Service.Displayname = "Intel(R) PRO/10GbE PCIe-N Network Connection Driver" ;----------------------------------------------------------------------------- ; Device Description Strings ;----------------------------------------------------------------------------- O10A6.DeviceDesc = "Intel(R) 82599 Multi-Function Network Device" N10F7.Generic.Description = "Intel(R) 10 Gigabit BR KX4 Dual Port Network Connection" N10F8.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Backplane Connection" N152A.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Backplane Connection with FCoE" N10F7.KX4.Dual.Description = "Intel(R) Ethernet Mezzanine Adapter X520-KX4-2" N1514.KX4.Dual.Description = "Intel(R) Ethernet X520 10GbE Dual Port KX4 Mezz" N10F8.KX4.KR.Dual.Description = "Intel(R) Ethernet X520 10GbE Dual Port KX4-KR Mezz" N10F8.KR.NDC.Description = "Intel(R) Ethernet 10G 2P X520-k bNDC" N1507.SFI.Dual.Description = "Intel(R) Ethernet ExpressModule X520-P2" N10F7.KX4.FEM.Description = "Sun Dual 10GbE PCIe 2.0 FEM" N1517.KR.Dual.Description = "Cisco UCS CNA M61KR-I Intel Converged Network Adapter" N154D.SFI.Dual.Description = "Intel(R) Ethernet 10G 2P X520 Adapter" HP10F8.KR.BLOM.Description = "HP Ethernet 10Gb 2-port 560FLB Adapter" HP10F8.KR.Dual.Description = "HP Ethernet 10Gb 2-port 560M Adapter" HP10FB.SFI.ALOM.Description = "HP Ethernet 10Gb 2-port 560FLR-SFP+ Adapter" HP10FB.SFI.ALOM.SP.Description = "HP Ethernet 10Gb 1-port P560FLR-SFP+ Adapter" HP10FB.SFI.LOM.Description = "HP Ethernet 10Gb 2-port 562i Adapter" N10FB.OCP.DP.Generic.Description = "Intel(R) Ethernet OCP Server Adapter X520-2" N1557.OCP.SP.Generic.Description = "Intel(R) Ethernet OCP Server Adapter X520-1" N10FB.SFI.FLEXLOM.Description = "Lenovo ThinkServer X520-2 AnyFabric" HP10FB.SFI.Dual.Description = "HP Ethernet 10Gb 2-port 560SFP+ Adapter" N10F9.Generic.Description = "Intel(R) 82599 10 Gigabit CX4 Dual Port Network Connection" N10FB.SFI.Single.Description = "Intel(R) Ethernet Server Adapter X520-1" N10FB.SFI.Dual.Description = "Intel(R) Ethernet Server Adapter X520-2" N10FB.CopperDA.Dual.Description = "Intel(R) Ethernet Server Adapter X520-DA2" N10FB.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Network Connection" N10FB.SFI.NDC.Description = "Intel(R) Ethernet 10G 4P X520/I350 rNDC" N10FB.SFI.ECNA.Description = "Intel(R) Ethernet 10GSFP+ DP Embedded CNA X520-2" N10FC.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Network Connection" N1529.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Network Connection with FCoE" N1557.Generic.Description = "Intel(R) 82599 10 Gigabit Network Connection" N151C.Copper.Dual.Description = "Intel(R) Ethernet Server Adapter X520-T2" N151C.Copper.Dual.Sun.Description = "Sun Dual 10GBASE-T LP" N151C.Generic.Description = "Intel(R) 82599 10 Gigabit TN Network Connection" N154A.SFI.Quad.Description = "Intel(R) Ethernet Converged Network Adapter X520-4" N1558.QSFP.Quad.Description = "Intel(R) Ethernet Converged Network Adapter X520-Q1" ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- [Strings.0C04] ; Chinese (Traditional) EnableLLI ="§C©µ¿ð§ÃÂ_" LLIPorts ="§C©µ¿ð§ÃÂ_³s±µ°ð" LLIPortBased ="³s±µ°ð¬°°ò¦" LLIPSHBased ="PSH ºX¸¹¬°°ò¦" InterruptModeration ="§ÃÂ_½Õ¸`" InterruptThrottleRate ="§ÃÂ_¸`¬y»Ö³t²v" Adaptive ="½Õ¾ã©Ê" Extreme ="·¥°ª" High ="°ª" Medium ="¤¤" Low ="§C" IPChksumOffv4 ="IPv4 Àˬd­È¨ø¸ü" TCPChksumOffv4 ="TCP Àˬd­È¨ø¸ü (IPv4)" UDPChksumOffv4 ="UDP Àˬd­È¨ø¸ü (IPv4)" LsoV2IPv4 ="¤j¶q¶Ç°e¨ø¸ü V2 (IPv4)" TCPChksumOffv6 ="TCP Àˬd­È¨ø¸ü (IPv6)" UDPChksumOffv6 ="UDP Àˬd­È¨ø¸ü (IPv6)" LsoV2IPv6 ="¤j¶q¶Ç°e¨ø¸ü V2 (IPv6)" ChksumOffTxRx ="Rx »P Tx ¤w±Ò¥Î" ChksumOffTx ="Tx ¤w±Ò¥Î" ChksumOffRx ="Rx ¤w±Ò¥Î" TransmitBuffers ="¶Ç¿é½w½Ä°Ï" ReceiveBuffers ="±µ¦¬½w½Ä°Ï" RSS ="±µ¦¬ºÝ½Õ¾ã¤ñ²v" NumRssQueues2 ="RSS ¦î¦Cªº³Ì¤j¼Æ¥Ø" RSSProfile ="RSS ¸ü¶q¥­¿Å³]©wÀÉ" Closest_Processor ="³Ì±µªñªº³B²z¾¹" Closest_Processor_Static ="³Ì±µªñªº³B²z¾¹¡]ÀRºA¡^" NUMA_Scaling ="NUMA ½Õ¾ã" NUMA_Scaling_Static ="NUMA ½Õ¾ã¡]ÀRºA¡^" Conservative_Scaling ="«O¦u½Õ¾ã" RssBaseProcNumber ="±Ò°Ê RSS CPU" MaxRssProcessors ="RSS ³B²z¾¹ªº³Ì¤j¼Æ¥Ø" NumaNodeId ="°¾¦nªº NUMA ¸`ÂI" default ="¨t²Î¹w³]­È" node0 ="¸`ÂI 0" node1 ="¸`ÂI 1" node2 ="¸`ÂI 2" node3 ="¸`ÂI 3" node4 ="¸`ÂI 4" node5 ="¸`ÂI 5" node6 ="¸`ÂI 6" node7 ="¸`ÂI 7" 1queue ="¤@­Ó¦î¦C" 2queues ="¨â­Ó¦î¦C" 4queues ="¥|­Ó¦î¦C" 8queues ="¤K­Ó¦î¦C" 16queues ="¤Q¤»­Ó¦î¦C" IPsecOffloadV2 ="IPsec ¨ø¸ü" IPsecAH ="¼ÐÃD»{ÃÒ (Auth Header) ¤w±Ò¥Î" IPsecESP ="ESP ¤w±Ò¥Î" IPSecAHESP ="¼ÐÃD»{ÃÒ (Auth Header) »P ESP ¤w±Ò¥Î" FCoEStartingNumaNodeId ="FCoE ±Ò°Ê NUMA ¸`ÂI" FCoENumaNodeCount ="FCoE NUMA ¸`ÂI¼Æ" FCoEStartingRSSCoreNumber ="FCoE ±Ò°Ê RSS ®Ö¤ß¸¹½X" FlowControl ="¬y¶q±±¨î" FlowControl_RxOnly ="Rx ¤w±Ò¥Î" FlowControl_TxOnly ="Tx ¤w±Ò¥Î" FlowControl_Full ="Rx »P Tx ¤w±Ò¥Î" PriorityVLANTag2 ="®M¥óÀu¥ý¶¶§Ç»P VLAN" PriorityVlanDisabled2 ="®M¥óÀu¥ý¶¶§Ç»P VLAN ¤w°±¥Î" PriorityEnabled2 ="®M¥óÀu¥ý¶¶§Ç¤w±Ò¥Î" PriorityVlanEnabled2 ="®M¥óÀu¥ý¶¶§Ç»P VLAN ¤w±Ò¥Î" VlanEnabled ="VLAN ¤w±Ò¥Î" SpeedDuplex ="³t«×»PÂù¤u" AutoNegotiation ="¦Û°Ê¥æ¯A" 1000Mb_Full_Duplex ="1.0 Gbps ¥þÂù¤u" 10Gb_Full_Duplex ="10 Gbps ¥þÂù¤u" Off ="Ãö³¬" Enabled ="±Ò¥Î" Disabled ="°±¥Î" Bytes4088 ="4088 ¦ì¤¸²Õ" Bytes9014 ="9014 ¦ì¤¸²Õ" LAA ="¥»¦aºÞ²z¦ì§}" JumboPacket ="¶W¤j«¬«Ê¥]" RSCIPv4 ="±µ¦¬°Ï¬qµ²¦X (IPv4)" LogLinkState ="µn¿ý³sµ²ª¬ºA¨Æ¥ó" Enable_PME ="±Ò¥Î PME" WakeOnMagicPacket ="³ê¿ô¯«©_«Ê¥]" WakeOnPattern ="¦b®æ¦¡¤Ç°t³ê¿ô" VMQ ="µêÀÀ¾÷¾¹¦î¦C" SRIOV ="SR-IOV" QOS ="NDIS QOS" SmartSpeed ="¦Û°Ê¤Á´«³t«×" ServiceName = "ixgbn" Intel = "Intel" EventLogMessageDllPath = "%SystemRoot%\System32\netevent.dll;%SystemRoot%\System32\ixnmsg.dll" DiskName = "Intel(R) PRO/10GbE Driver Disk" Service.Displayname = "Intel(R) PRO/10GbE PCIe-N Network Connection Driver" ;----------------------------------------------------------------------------- ; Device Description Strings ;----------------------------------------------------------------------------- O10A6.DeviceDesc = "Intel(R) 82599 Multi-Function Network Device" N10F7.Generic.Description = "Intel(R) 10 Gigabit BR KX4 Dual Port Network Connection" N10F8.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Backplane Connection" N152A.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Backplane Connection with FCoE" N10F7.KX4.Dual.Description = "Intel(R) Ethernet Mezzanine Adapter X520-KX4-2" N1514.KX4.Dual.Description = "Intel(R) Ethernet X520 10GbE Dual Port KX4 Mezz" N10F8.KX4.KR.Dual.Description = "Intel(R) Ethernet X520 10GbE Dual Port KX4-KR Mezz" N10F8.KR.NDC.Description = "Intel(R) Ethernet 10G 2P X520-k bNDC" N1507.SFI.Dual.Description = "Intel(R) Ethernet ExpressModule X520-P2" N10F7.KX4.FEM.Description = "Sun Dual 10GbE PCIe 2.0 FEM" N1517.KR.Dual.Description = "Cisco UCS CNA M61KR-I Intel Converged Network Adapter" N154D.SFI.Dual.Description = "Intel(R) Ethernet 10G 2P X520 Adapter" HP10F8.KR.BLOM.Description = "HP Ethernet 10Gb 2-port 560FLB Adapter" HP10F8.KR.Dual.Description = "HP Ethernet 10Gb 2-port 560M Adapter" HP10FB.SFI.ALOM.Description = "HP Ethernet 10Gb 2-port 560FLR-SFP+ Adapter" HP10FB.SFI.ALOM.SP.Description = "HP Ethernet 10Gb 1-port P560FLR-SFP+ Adapter" HP10FB.SFI.LOM.Description = "HP Ethernet 10Gb 2-port 562i Adapter" N10FB.OCP.DP.Generic.Description = "Intel(R) Ethernet OCP Server Adapter X520-2" N1557.OCP.SP.Generic.Description = "Intel(R) Ethernet OCP Server Adapter X520-1" N10FB.SFI.FLEXLOM.Description = "Lenovo ThinkServer X520-2 AnyFabric" HP10FB.SFI.Dual.Description = "HP Ethernet 10Gb 2-port 560SFP+ Adapter" N10F9.Generic.Description = "Intel(R) 82599 10 Gigabit CX4 Dual Port Network Connection" N10FB.SFI.Single.Description = "Intel(R) Ethernet Server Adapter X520-1" N10FB.SFI.Dual.Description = "Intel(R) Ethernet Server Adapter X520-2" N10FB.CopperDA.Dual.Description = "Intel(R) Ethernet Server Adapter X520-DA2" N10FB.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Network Connection" N10FB.SFI.NDC.Description = "Intel(R) Ethernet 10G 4P X520/I350 rNDC" N10FB.SFI.ECNA.Description = "Intel(R) Ethernet 10GSFP+ DP Embedded CNA X520-2" N10FC.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Network Connection" N1529.Generic.Description = "Intel(R) 82599 10 Gigabit Dual Port Network Connection with FCoE" N1557.Generic.Description = "Intel(R) 82599 10 Gigabit Network Connection" N151C.Copper.Dual.Description = "Intel(R) Ethernet Server Adapter X520-T2" N151C.Copper.Dual.Sun.Description = "Sun Dual 10GBASE-T LP" N151C.Generic.Description = "Intel(R) 82599 10 Gigabit TN Network Connection" N154A.SFI.Quad.Description = "Intel(R) Ethernet Converged Network Adapter X520-4" N1558.QSFP.Quad.Description = "Intel(R) Ethernet Converged Network Adapter X520-Q1" ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- ;----------------------------------------------------------------------------- ;-----------------------------------------------------------------------------