Edit D:\app\Administrator\product\11.2.0\dbhome_1\owb\rtp\sql\UpdateControlCenter.sql
set serveroutput on; set verify off; prompt prompt This sql script sets the host:port:service parameters for a control center prompt in the OWB Client Repository. It must be run from user OWBSYS. prompt prompt The connection type must be host:port:service and cannot be changed prompt using this script. prompt prompt The default control center (DEFAULT_CONTROL_CENTER) cannot be changed prompt using this script. prompt prompt accept WORKSPACE_NAME CHAR PROMPT 'Enter Workspace Name: ' accept USER_NAME CHAR PROMPT 'Enter Workspace User Name: ' accept CONTROL_CENTER_NAME CHAR PROMPT 'Enter Control Center Name: ' accept HOST CHAR PROMPT 'Host: ' accept PORT CHAR PROMPT 'Port: ' accept SERVICE CHAR PROMPT 'Service Name: ' declare v_elementid number(9); procedure updatestringprop (p_name varchar2, p_value varchar2) as begin update cmpstringpropertyvalue_v set value=p_value where logicalname = p_name and firstclassobject=v_elementid; end; procedure insertstringprop (p_name varchar2, p_value varchar2) as v_uoid varchar2(255); v_seq number(9); begin select sys_guid(), cwmseq.nextval into v_uoid, v_seq from dual; dbms_output.put_line( p_name || ' Not Found Inserting' ); insert into cmpstringpropertyvalue_v( CLASSNAME,CREATEDBY,CREATIONTIMESTAMP, CUSTOMERDELETABLE,CUSTOMERRENAMABLE, EDITABLE,ELEMENTID,IMPORTED, LOGICALNAME,METADATASIGNATURE,NOTM,PERSISTENT,SEEDED, UOID,UPDATEDBY,UPDATETIMESTAMP,POSITION,PROPERTYOWNER, COMPLETED, DELETEINOVERRIDE, OVERRIDEATTRIBUTES, OVERRIDECHILDREN, OVERRIDEROLES, FIRSTCLASSOBJECT,VALUE) values ('CMPStringPropertyValue', USER, SYSDATE, '1', '0', '1', v_seq, '0', p_name, '9999999999', '0', '1', '0', v_uoid, USER, SYSDATE, '0', v_elementid, '0', '0', '0', '0', '0', v_elementid, p_value); end; procedure update_host_port_service as begin dbms_output.put_line('Updating CMPLocation_Host = ' || '&HOST'); updatestringprop('CMPLocation_Host', '&HOST'); if SQL%NOTFOUND THEN insertstringprop('CMPLocation_Host', '&HOST'); END IF; dbms_output.put_line('Updating CMPLocation_Port = ' || '&PORT'); updatestringprop('CMPLocation_Port', '&PORT'); if SQL%NOTFOUND THEN insertstringprop('CMPLocation_Port', '&PORT'); END IF; dbms_output.put_line('Updating CMPLocation_ServiceName = ' || '&SERVICE'); updatestringprop('CMPLocation_ServiceName', '&SERVICE'); if SQL%NOTFOUND THEN insertstringprop('CMPLocation_ServiceName', '&SERVICE'); END IF; update CMPRuntimeLocation_v set host='&HOST' , port='&PORT' where name = '&CONTROL_CENTER_NAME'; end; function getworkspace return boolean as v_workspaceid number; begin select workspace_id into v_workspaceid from workspace_assignment where workspace_name = UPPER('&WORKSPACE_NAME') and user_name = UPPER('&USER_NAME'); dbms_output.put_line('Select Workspace Id for workspace ' || '&WORKSPACE_NAME' || ' and user ' || '&USER_NAME'); dbms_output.put_line('Workspace id = ' || v_workspaceid); owb_workspace_manager.set_workspace(v_workspaceid); return true; EXCEPTION WHEN NO_DATA_FOUND THEN dbms_output.put_line('Workspace id not found for workspace ' || '&WORKSPACE_NAME' || ' and user ' || '&USER_NAME'); return false; WHEN OTHERS THEN dbms_output.put_line('Other Error'); return false; end; function getruntimelocation return boolean as v_loctype varchar2(40); v_loctypeversion varchar2(40); begin select loctype, elementid into v_loctype, v_elementid from CMPRuntimeLocation_v where name = '&CONTROL_CENTER_NAME'; dbms_output.put_line('Update location properties for ' || '&CONTROL_CENTER_NAME'); dbms_output.put_line('Location Type = ' || v_loctype); return true; EXCEPTION WHEN NO_DATA_FOUND THEN dbms_output.put_line('Control Center ' || '&CONTROL_CENTER_NAME' || ' not found'); return false; end; procedure updateruntimelocation as v_connectiontype varchar2(255); v_found boolean; v_workspace boolean; begin v_workspace := getworkspace; if v_workspace = true then v_found := getruntimelocation; if v_found = true then dbms_output.put_line('Control Center ' || '&CONTROL_CENTER_NAME' || ' Found'); select value into v_connectiontype from cmpstringpropertyvalue_v where logicalname = 'CMPLocation_ConnectionType' and propertyowner = v_elementid; if v_connectiontype = 'HOST:PORT:SERVICE' then dbms_output.put_line('Connection Type = HOST:PORT:SERVICE Updating...'); update_host_port_service; else dbms_output.put_line('Connection Type ' || v_connectiontype || ' cannot be updated'); end if; end if; end if; EXCEPTION WHEN NO_DATA_FOUND THEN dbms_output.put_line('Connection Type = Default HOST:PORT:SERVICE Updating...'); update_host_port_service; end; begin updateruntimelocation; commit; end; /
Ms-Dos/Windows
Unix
Write backup
jsp File Browser version 1.2 by
www.vonloesch.de